VALVE REPLACEMENT
Back Burner
11) Unplug the 3 black wires at the DC Sparker.
12) Unplug the 5 wires at the valve (2 grey, 2 red and 1 black.
13) Reach in and grab the black and red wires leading to the solenoid valve and disconnect them.
Solenoid Valve
10) Remove back air box by removing 2 screws, one on the left and one on the right side and pull out.
Slide burner to the right and lift out.

MAINTENANCE

VALVE REPLACEMENT

1) Shut off the main gas supply and unplug 9) the power to the ECS system.

2)Remove the main gas line pipe from the gas valve.

3)Remove logs and brick panels if installed.

4)Remove the log stand by undoing the 2 screws, one on the left and right side.

Log Stand

5)Remove the front air box by undoing the 3 screws.

14)Remove all 22 valve tray screws and carefully lift out the valve tray. Disonnect the Manual Control Panel from the valve tray by disconnecting the two screws.

15)Disconnect the compression fitting at the solenoid valve.

16)Remove the solenoid valve from the main valve.

Solenoid Valve

Compression Fittings

MAINTENANCE

Front Air Box

6)Remove the front burner by removing the 2 screws and swing the burner to the left and slide out.

7)Carefully remove the base brick panel.

8)Remove the 2 screws on the back burner. Loosen the set collar screw and disonnect the aeration adjustement wire.

Back Burner

Set collar screw

17)Disconnect the thermopile wires (TP/TH & TP) from the valve. See image below.

18)Undo the pilot tube from the valve with a 7/16" wrench. See image below.

19)Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench.

Thermopile

Thermocouple Pilot Nut

Wire

Wire

20)Remove the 4 Phillips head screws from the sides of the valve bracket and remove valve.

Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible.