MANTEL CLEARANCES

INSTALLATION

MANTEL CLEARANCES

Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of louver opening are shown in the diagram below. Mantel may be installed anywhere in the shaded area.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.

INSTALLATION

Note: Ensure that any paint used on the mantel or on the facing is "heat resistant" or the paint may discolour.

14

12

10

8

6

4

2

0

20

13” Mantel

 

 

 

 

 

18

 

 

 

 

 

Combustible Material

16

8” Mantel

 

 

14

 

Non-Combustible

 

1” Mantel

12

Header (On Edge)

 

 

 

21”

 

 

Non-Combustible

 

 

Material

10

 

 

 

 

 

 

17”

 

Top Standoff

8

 

 

 

 

 

6

12”

1/4”

 

 

1/2”

 

 

10

 

 

-

 

4

 

 

-

 

 

 

8

2

Full Screen Doors

 

 

0

Top

 

Top

 

 

 

 

Nailing

33”

Louvers

 

 

Strip

to floor

 

 

 

Side View

MANTEL LEG CLEARANCES

Combustible mantel leg clearances as per diagram:

Mantel Leg Clearances - Flush Front

Mantel Leg Clearances - Full Screen Door

Non Combustible Facing

P40

Fireplace

 

 

 

 

6”

 

 

 

P40

 

 

 

 

 

 

 

 

 

 

 

Fireplace

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum

1-1/2" projection at 2" minimum clearance.

Mantelleg

Mantelleg

2”

 

7-1/4”

Allowable mantel leg

projection.

1-1/2"

 

6”

 

 

 

 

Full Screen Door

2”

Maximum

1-1/2" projection at 2" minimum clearance.

Mantelleg

Mantelleg

1-1/2"

6”

2”

 

 

 

7-1/4”

Allowable mantel leg

projection.

10

Regency® P40-1 Direct Vent Gas Fireplace

Page 10
Image 10
Regency P40-NG1, P40-LP1 installation manual Mantel Clearances, Mantel Leg Clearances, P40 Fireplace, 7-1/4”, 1-1/2