Regency P40-NG1 Control Module Replacement, Backup Battery Replacement, within Power Module

Models: P40-LP1 P40-NG1

1 56
Download 56 pages 11.46 Kb
Page 48
Image 48
CONTROL MODULE

MAINTENANCE

CONTROL MODULE

REPLACEMENT

1)Unplug the power source.

2)Remove the Power Module by lifting it up off of the velcro and pull out.

Power Module

3)Remove the Control Module by lifting it up off of the velcro and pull out.

Control Module

4)Remove the Heat Shield from the Control Module by removing the 2 screws.

Heat Shield

5)Unplug all wire harnesses and manual control box cable plugged into the Control module.

6)Replace the Control Module and reverse steps to re-install.

BACKUP BATTERY

REPLACEMENT

(within Power Module)

NOTE: The 9V battery operates the rear burner under power outage conditions.

The AA battery operates the DC Sparker for lighting the pilot.

1)Unplug the power source.

2)Remove the Power Module by lifting it up off of the velcro and pull out.

Power Module

3)Remove the Power Module cover by removing the 2 screws, one on each side of the box.

MAINTENANCE

4)Replace the 9V and AA battery and reverse steps to re-install.

48

Regency® P40-1 Direct Vent Gas Fireplace

Page 48
Image 48