DOOR GLASS

MAINTENANCE

DOOR GLASS

 

FAN REPLACEMENT

Your Regency® fireplace is supplied with high

1)

Unplug the power source.

temperature 5mm-Ceramic glass. If your glass

 

 

requires cleaning, we recommend using an

2)

Remove the power module by lifting it up

approved glass cleaner available at all authorized

 

off of the velcro and pull out.

dealers. Do not use abrasive materials.

 

 

 

6)Remove the fan ground wires.

CAUTION & WARNINGS:

*Do not clean when the glass is hot.

*The use of substitute glass will void all product warranties.

*Care must be taken to avoid breakage of the glass.

*Do not strike or abuse the glass.

*Do not operate this fireplace without the glass front or with a cracked or broken glass front.

*Wear gloves when removing damaged or broken glass.

*Replacement of the glass panel(s) should be done by a licensed or qualified service per son.

GLASS REPLACEMENT

In the event that you break your glass by impact, purchase your replacement from an authorized Regency® dealer only.

Replacement glass is shipped already installed into the door frame. Reinstall as per Glass Door Installation in "Standard Flush Door" section.

CAUTION: Wear gloves when removing damaged or broken glass.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person.

Power Module

3)Undo the wire holder by releasing tab.

4)Remove the Control module by lifting it up and off to the side.

7)Disconnect the brown and blue wires connected to the J1 harness.

8)Release the 2 wire tabs.

9)Remove both fans by lifting up off of the pins and tilt sideways and then slide to the left of the firebox and pull out carefully.

10)Reverse steps to re-install.

MAINTENANCE

Control Module

5)Unplug the J1, J2 and J3 harness at the ECS module and pull out the Control module.

NOTE: To facilitate easier re-installation of the fans, apply some lubricante to the rubber grom- mets at the base of the fan bracket.