Regency P40-LP1, P40-NG1 installation manual Offset Pipe Selection, 58DVA-RD

Models: P40-LP1 P40-NG1

1 56
Download 56 pages 11.46 Kb
Page 17
Image 17

INSTALLATION

Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.

Description

 

Simpson

 

Simpson

 

Selkirk

Metal-Fab®

 

®

Direct Vent GS®

 

 

 

Direct Vent Pro

 

Discontinued

Direct-Temp™

Sure Seal

 

 

 

 

 

 

Round Support / Radiation Sheild

N/A

 

N/A

 

N/A

N/A

Flat Flashing

 

N/A

 

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

Attic Insulation Shield 12”

58DVA-IS - N/A from FPI

58DVA-IS - N/A from FPI

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Basic Horizontal Termination Kit (A)

N/A

 

N/A

 

5DT-HKA

N/A

Horizontal Termination Kit (B)

58DVA-KHA

 

N/A

 

5DT-HKB

N/A

Vertical Termination Kit

58DVA-VCH

 

1291

 

 

5DT-VKC

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Wind Vertical Cap

N/A

 

N/A

 

N/A

N/A

High Wind Horizontal Cap

DISC.

 

1285

 

 

N/A

N/A

Horizontal Square Termination Cap

N/A

 

1284

 

 

5DT-HHC

5DHT

Vertical Termination Cap

N/A

 

N/A

 

5DT-HVC

5DVT

Storm Collar

 

58DVA-SC

 

1253

 

 

5DT-SC

5DSC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustable Flashing, 0/12-6/12

58DVA-F6

 

1243

 

 

5DT-AF6

5DF

Adjustable Flashing, 6/12-12/12

58DVA-F12

 

1243S

 

5DT-AF12

5DF-12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vinyl Siding Standoff

58DVA-VSS

 

1250

 

 

5DT-VS

5DVS

Vinyl Siding Shield Plate

N/A

 

N/A

 

5DT-VSP

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Snorkel Termination 14”

58DVA-SNK14

 

1282

 

 

5DT-ST14

5DST14

Snorkel Termination 36”

N/A

 

1281

 

 

5DT-ST36

5DST36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Restrictor Disk

 

58DVA-RD

 

N/A

 

N/A

N/A

Colinear Flex Liner Adapter (3” Ø)

N/A

 

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FPI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

946-604/P

Simpson Direct Vent Vent Guard (Optional)

 

946-623/P

 

AstroCap XL Horizontal Cap

 

770-994

Rigid Pipe Adapter (Must use with all Rigid Piping)

 

946-506/P

 

Vent Guard (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

946-625

 

Vinyl Siding Standoff - AstroCap XL

 

 

 

 

 

 

 

 

 

 

*NOTE: When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (5DDA) or 90º Starter Elbow (5D90A) must be used in conjunction with FPI Rigid Pipe Adaptor (770-994).

L676 & L900 Direct Vent Fireplace

IMPORTANT NOTE

A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.

The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications.

Only the AstroCap XL and Snorkels are certified for horizontal terminations.

INSTALLATION

Offset Pipe Selection:

Use this table to determine offset pipe lengths.

Pipe Length

5” x 8” Venting

 

 

Run (X)

Rise (Y)

 

 

 

 

0”(0mm)

5-11/16”(144mm)

15-5/16”(389mm)

 

 

 

6”(152mm)

8-13/16”(224mm)

18-7/16”(468mm)

 

 

 

9”(229mm)

10-15/16”(278mm)

20-9/16”(522mm)

 

 

 

12”(305mm)

13”(330mm)

22-11/16”(576mm)

 

 

 

24”(610mm)

21-7/16”(697mm)

31-1/16”(789mm)

 

 

 

36”(914mm)

29-13/16”(757mm)

39-7/16”(1002mm)

 

 

 

48”(1219mm)

38-1/4”(972mm)

47-7/8”(1216mm)

 

 

 

L

Y

X

For specific instructions or details on particular venting components please visit the following websites:

Simpson Direct Vent Pro: www.duravent.com

Selkirk Direct-Temp: www.selkirkcorp.com

Metal-Fab Sure Seal: www.mtlfab.com

NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present a possible fire hazard.

Regency® P40-1 Direct Vent Gas Fireplace

17

Page 17
Image 17
Regency P40-LP1, P40-NG1 installation manual Offset Pipe Selection, 58DVA-RD

P40-LP1, P40-NG1 specifications

The Regency P40-LP1 and P40-NG1 are notable advancements in the realm of modern technology, particularly designed for energy efficiency and enhanced performance in various applications. These two models cater to the diverse needs of industries striving for both sustainability and productivity.

The P40-LP1 is engineered with a focus on low-pressure applications, utilizing cutting-edge technology to ensure optimal performance in energy consumption. This model features an advanced energy management system that intelligently adjusts power usage based on demand, which not only reduces operational costs but also minimizes the environmental impact. Its compact design and lightweight materials allow for easy installation in various settings, making it a versatile option for multiple industries.

On the other hand, the P40-NG1 is tailored for natural gas applications, making it an ideal choice for environments where natural gas is the primary energy source. This model is equipped with high-efficiency burners that maximize combustion efficiency, producing fewer emissions compared to traditional systems. The P40-NG1 also incorporates an integrated control system, providing users with real-time data monitoring to optimize performance and facilitate preventative maintenance.

Both models are constructed with durable materials designed to withstand harsh operating conditions, ensuring longevity and reliability. Advanced insulation technology further enhances their efficiency by reducing heat loss, allowing these systems to maintain consistent performance over extended periods.

A standout feature of the P40 series is its commitment to user-friendliness. The intuitive interface allows operators to easily navigate settings and access critical system information with minimal training. Additionally, these units are compatible with smart technologies, enabling seamless integration into existing infrastructure for enhanced operational oversight.

In summary, the Regency P40-LP1 and P40-NG1 embody the future of energy solutions, combining efficiency, adaptability, and user-focused design. Whether it’s for low-pressure or natural gas applications, these products deliver reliable performance while adhering to environmental standards. With ongoing advancements in their technology, the P40 series stands as a testament to Regency’s dedication to innovation and sustainability in the energy sector.