INSTALLATION
Vertical Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
INSTALLATION
Option V | H | V + V1 |
A)0' Min. 2' Max. 1' Min.
B)1' Min. 4' Max. 2' Min.
C)2' Min. 5' Max. 3' Min.
D)3' Min. 6' Max. 4' Min.
E)4' Min. 7' Max. 5' Min.
F)5' Min. 8' Max. 6' Min.
With these options, max. total pipe length is 30 feet with min. of 6 feet total vertical and max. 8 feet total horizontal.
Please note min. 1 foot between 90o elbows is required.
V1
VENT RESTRICTOR SETTING:
When total vertical exceeds total horizontal by 2x the vent restrictor setting is set to 1.
H V
For additional vertical venting with 2 x 90o elbows, refer to next page.
Vertical Venting with Three (3) 90o Elbows
One 90o elbow = Two 45o elbows.
V1
H1 | H | V |
|
|
Option | V H + H1 V + V1 |
A)0' Min. 2' Max. 3' Min.
B)1' Min. 2' Max. 3' Min.
C)2' Min. 3' Max. 4' Min.
D)3' Min. 4' Max. 6' Min.
E)4' Min. 5' Max. 7' Min.
F)5' Min. 6' Max. 8' Min.
G)6' Min. 7' Max. 9' Min.
H)7' Min. 8' Max. 10' Min.
With these options, max. total pipe length is 30 feet with min. of 10 feet total vertical and max. 8 feet total horizontal.
Please note min. 1 foot between 90o elbows is required.
VENT RESTRICTOR SETTING:
When total vertical exceeds total horizontal by 3x the vent restrictor setting is set to 1.