Regency P40-LP1, P40-NG1 installation manual Exterior Vent Termination Requirements, Installation

Models: P40-LP1 P40-NG1

1 56
Download 56 pages 11.46 Kb
Page 13
Image 13
EXTERIOR VENT TERMINATION REQUIREMENTS

INSTALLATION

EXTERIOR VENT TERMINATION REQUIREMENTS

INSTALLATION

A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)

B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)

C= Clearance to permanently closed window *#(min. 12"/30cm)

D= Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of (24"/60cm) from the centerline of the terminal (min. 23") check with local code.

E= Clearance to unventilated soffit (min. 15"/38cm)

F= Clearance to outside corner: 13"

G= Clearance to inside corner: 13"

H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from the centerline of the regulator.

J= Clearance to service regulator vent outlet *(min. 36"/90cm)

K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance *(12"/30cm) #(9"/23cm)

L= Clearance to a mechanical air supply inlet *(6'/1.83m) #3' (91cm) above if within 10' (3m) horizontally.

M= Clearance above paved sidewalk or a paved driveway located on public property *(min. 84"/2.1m)

N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)

Note:

-Excluding direct vent or non-condensing appliances, a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

-Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

-If the vent termination is accessible, a certified guard shall be installed.

*(Canada) As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.

# (US) In accordance with the current ANSI Z223.1/NFPA 54, Natioinal Fuel Gas Code.

Regency® P40-1 Direct Vent Gas Fireplace

13

Page 13
Image 13
Regency P40-LP1, P40-NG1 installation manual Exterior Vent Termination Requirements, Installation