Regency P40-LP1 Gas Line Installation, Pilot Adjustment, High Elevation, Front Burner Orifice

Models: P40-LP1 P40-NG1

1 56
Download 56 pages 11.46 Kb
Page 25
Image 25
For 0 to 4500 feet altitude

INSTALLATION

P40-NG1 SYSTEM DATA

For 0 to 4500 feet altitude

 

Front Burner Orifice:

#44

Back Burner Orifice:

#35

 

 

Max. Input Rating

45,000 Btu/h

Min. Input Rating

13,000 Btu/h

 

 

Supply Pressure

min.5.0" w.c.

 

 

 

Manifold Pressure

 

 

(High)

3.5"+/- 0.3"w.c.

Log Set: Ceramic fibre,

8 per set + ember bed.

Vent System: Simpson Dura-Vent Direct

Vent System, Regency® Flex Kit, Selkirk

Direct-Temp

P40-LP1 SYSTEM DATA

Conversion Kit# 502-969

 

For 0 to 4500 feet altitude

 

Front Burner Orifice:

#55

Back Burner Orifice:

#53

 

 

Max. Input Rating

43,000 Btu/h

Min. Input Rating

12,000 Btu/h

 

 

Supply Pressure

min.12.0" w.c.

 

 

 

Manifold Pressure

 

 

(High)

10"+/- 0.5" w.c.

Log Set: Ceramic fibre,

8 per set + ember bed.

Vent System: Simpson Dura-Vent Direct

Vent System, Regency® Flex Kit, Selkirk

Direct-Temp

GAS LINE

INSTALLATION

The gas line can be brought through the bottom right of the appliance. The gas valve is situated on the bottom of the unit.

The gas line connection may be made of rigid pipe, copper pipe or an approved flex connector. (If you are using rigid pipe, ensure that the valve can be removed for servicing.) Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code.

For USAinstallations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.

When using copper or flex connectors use only approved fittings. Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and flex connectors are usually considered to meet this requirement.

IMPORTANT: Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing.

PILOT ADJUSTMENT

Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile, 1 around the thermocouple and 1 flowing across the burner (it does not have to be touching the burner).

Note: If you have an incorrect flame pattern, contact your Regency® dealer for further instructions.

Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear burner or thermopile or thermocouple.

INSTALLATION

HIGH ELEVATION

This unit is approved in Canada for altitude 0 to 4500 ft. (CAN1 2.17-M91).

Regency® P40-1 Direct Vent Gas Fireplace

25

Page 25
Image 25
Regency P40-LP1 Gas Line Installation, Pilot Adjustment, High Elevation, For 0 to 4500 feet altitude, Front Burner Orifice