Regency P40-NG1 Venting Arrangements, Installation, AstroCap XL, Regency Direct Vent Flex System

Models: P40-LP1 P40-NG1

1 56
Download 56 pages 11.46 Kb
Page 14
Image 14
VENTING ARRANGEMENTS

INSTALLATION

INSTALLATION

VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency® Direct Vent System

These venting systems, in combination with the P40 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Requirements" section.

Regency® Direct Vent (Flex) System

 

AstroCap XL

Termination Kit (Part# 946-618) includes all

 

 

(Part# 946-623/P)

the parts needed to install the P40 with a

 

maximum run of 6 feet.

 

 

1)

8" dia. flexible liner (6 ft. length)

 

 

2)

5" dia. flexible liner (6 ft. length)

 

 

3)

spring spacers (4)

Wall Thimble

 

4)

thimble

 

(required in Canada only)

5)

AstroCap XL termination cap (1)

6)

screws (12)

 

Vinyl Siding

7)

tube of Mill Pac (1)

 

 

Standoff

8)

plated screws (8)

 

 

 

9)

screws #8 x 1-1/2" Drill Point,

5” dia. flue pipe

 

 

Stainless Steel (4)

 

 

10) vinyl siding standoff

8" dia.

 

 

 

spring spacer

If longer runs are needed, the Regency® Direct

Flue pipe

 

Vent system (Flex) Part# 946-616 includes all the parts needed to install the P40 with a maximum 10' run.

1) 8" dia. flexible liner (10 ft. length)

2) 5" dia. flexible liner (10 ft. length)

3)spring spacers (7)

4) thimble (2)

5)AstroCap XL termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1-1/2" Drill Point,

Stainless Steel (4)

10) vinyl siding standoff

Notes:

1)Liner sections should be continuous without any joints or seams.

2)Only Flex pipe purchased from FPI may be used for Flex installations.

3)Horizontal vent must be supported every 3 feet. (For 10' flex kit 946-616 only.)

14

Regency® P40-1 Direct Vent Gas Fireplace

Page 14
Image 14
Regency P40-NG1 Venting Arrangements, Installation, AstroCap XL, Regency Direct Vent Flex System, maximum run of 6 feet