VENTING ARRANGEMENTS
HORIZONTAL TERMINATION (FLEX)
Regency® Direct Vent System
These venting systems, in combination with the P40 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Requirements" section.
Regency® Direct Vent (Flex) System |
| AstroCap XL | ||
Termination Kit (Part# |
| |||
| (Part# | |||
the parts needed to install the P40 with a |
| |||
maximum run of 6 feet. |
|
| ||
1) | 8" dia. flexible liner (6 ft. length) |
|
| |
2) | 5" dia. flexible liner (6 ft. length) |
|
| |
3) | spring spacers (4) | Wall Thimble |
| |
4) | thimble |
| ||
(required in Canada only) | ||||
5) | AstroCap XL termination cap (1) | |||
6) | screws (12) |
| Vinyl Siding | |
7) | tube of Mill Pac (1) |
| ||
| Standoff | |||
8) | plated screws (8) |
| ||
|
| |||
9) | screws #8 x | 5” dia. flue pipe |
| |
| Stainless Steel (4) |
|
| |
10) vinyl siding standoff | 8" dia. |
| ||
|
| spring spacer | ||
If longer runs are needed, the Regency® Direct | Flue pipe | |||
|
Vent system (Flex) Part#
1) 8" dia. flexible liner (10 ft. length)
2) 5" dia. flexible liner (10 ft. length)
3)spring spacers (7)
4) thimble (2)
5)AstroCap XL termination cap (1)
6)screws (12)
7)tube of Mill Pac (1)
8)plated screws (8)
9)screws #8 x
Stainless Steel (4)
10) vinyl siding standoff
Notes:
1)Liner sections should be continuous without any joints or seams.
2)Only Flex pipe purchased from FPI may be used for Flex installations.
3)Horizontal vent must be supported every 3 feet. (For 10' flex kit