14)Re-install pilot shield.

15)Set aeration on both front and rear burner for LP gas;

Rear 1/4"

Front 1/8"

16)Reverse steps 8 to 4.

17)Remove the Power Module by lifting it up off of the velcro and move it over to the side.

Power Module

18)Remove the Control Module, located behind the power module, by lifting it up off of the velcro.

Control Module

19)Place the J9 jumper using needle nose pliers, located under the heat shield.

J9 Jumper

20)Reverse steps 18 to 17. Be careful not to pinch wires.

21)Remove the 2 wires connected to the modulating coil.

Modulating Coil

22)Using a Torx T20, or slotted screwdriver, remove and discard the three pressure regulator mounting screws and rubber diaphram.

23)Insure that the new rubber gasket is properly positioned and install the new modulating pressure regulator assembly to the valve using the screws supplied with the kit. Tighten screws securely.

24)Reattach 2 wires to modulating coil.

25)Install the enclosed identification label to the valve body where it can be easily seen. The label is found in the coil pack- age.

26)Attach the LP conversion decal near or on top of the serial # decal located on a metal plate under the unit.

27)Replace the red "Propane" label with the yellow "Natural Gas" label on the valve assembly.

28)Ensure proper installation of venting is complete, gas line is connected and then turn on power to unit.

29)Check for gas leaks.

30)Check inlet (5" wc) and outlet (3.5" wc) pressures.

31)Check operation of flame control using the manual control box located on the right side under the firebox.

32)Re-install logs and flush door. Check for proper flame appearance and glow on logs.

WARNING!

This conversion kit should be installed by a qualified service agency in ac- cordance with the authority having jurisdiction. If the information in these instructions are not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is respon- sible for the proper installation of this kit. The installation is not proper and complete until the operation of the con- verted appliance is checked as speci- fied in the manufacturer's instructions supplied with the kit.

Installer Notice:

These instructions must be left

with the appliance.

J9 Jumper Location

30