FULL SCREEN DOORS

INSTALLATION

FULL SCREEN DOORS

INSTALLATION

1)Before beginning the installation; if already installed, remove the Top and Bottom Louvers, the Manual Control Box and the Glass Door from the unit. Refer to the manual for instructions and reverse the steps (See Page 32).

2)Remove the Screen Doors from the Full Screen Door Frame by fully opening the doors and lifting up off of the hinges. See important note in step 9.

3)Install the Hinges to the Hinge Brackets on the left and right side of the bottom of the outer frame, se- cure using 2x #8 Self Tapping Phillips Screws per hinge.

4)Full Screen Door Frame Installation

a)Before attaching the Full Screen Door Frame to the unit, loosen the left and right side #8 Self Tapping Phillips Screws located on the inside top of the outer frame of the appliance. Also remove the center screw.

b)Slide the cut-outs in the Top and Bottom Flange of the Full Screen Door Frame under the screw heads which were loosened in step 4a. Once the Frame is in place, tighten the screws to secure. Also re-secure the top center screw through the oblong hole.

Full Screen

Door Frame

Cut Outs

Remove the center screw

Inside

Top of

Outer

Frame

Loosen these

four screws

Leave these two screws secured

Oblong

Hole

Top Flange

Bottom Flange

Cut Outs

Rear view of Full

Screen Door

Frame Shown

Leave these two screws secured

NOTE: Should the finished wall protrude beyond the face of the unit, you can accommodate up to 1/2" discrepancy in depth.