Regency P40-LP1, P40-NG1 Horizontal Venting with Two 2 90o Elbows, Option, V + V1 H + H1

Models: P40-LP1 P40-NG1

1 56
Download 56 pages 11.46 Kb
Page 19
Image 19
Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

 

 

 

One 90o elbow = Two 45o elbows.

INSTALLATION

 

Option

 

V

H + H1

With

these options,

 

A)

2'

Min.

2' Max.

maximum total pipe length

 

 

B)

3'

Min.

5' Max.

is 30 feet with minimum

 

 

C)

4'

Min.

6' Max.

of 6

feet total vertical

 

 

and maximum 8 feet total

 

 

 

 

 

 

 

 

D)

5'

Min.

7' Max. horizontal.

 

 

E)

6' Min.

8' Max.

 

 

 

 

VENT RESTRICTOR SETTING:

 

 

 

H1

When total vertical exceeds total horizontal by 2x the vent

 

restrictor setting is set to 1.

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

Please note minimum 1 foot between 90o elbows is

 

 

required.

 

 

 

 

 

 

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 H + H1

A)0' Min. 1' Max. 1' Min. 1' Max.

B)1' Min. 2' Max. 3' Min. 3' Max.

C)2' Min. 2' Max. 5' Min. 4' Max.

D)3' Min. 2' Max. 7' Min. 5' Max.

E)4' Min. 3 Max. 9' Min. 6' Max.

F)5' Min. 4' Max. 10' Min. 7' Max.

G)6' Min. 5' Max. 11' Min. 8' Max.

H)7' Min. 6' Max. 12' Min. 9' Max.

With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

When total vertical exceeds total horizontal by 3x the vent restrictor setting is set to 1.

Regency® P40-1 Direct Vent Gas Fireplace

19

Page 19
Image 19
Regency P40-LP1 Horizontal Venting with Two 2 90o Elbows, Horizontal Venting with Three 3 90o Elbows, Option, H + H1