Rental Cooling Evaporative Condensers Cooling Towers Fluid Coolers Rental Cooling E
| | | | |
Condensers | Cooling Towers Fluid Coolers Rent l Cooling Evap rative Condensers | Cool |
Fluid Coolers | Marley Package Products | | Re |
Rental Cooling Evaporative Condensers Cooling Towers Fluid Coolers |
ing | As a cooling industry leader in the green movement, SPX Cooling Technologies provides | | |
Evaporative Condensers Cooling Towers Fluid Coolers Rental Cooling Evaporative C |
| the highest-quality evaporative cooling towers, fluid coolers and evaporative condensers to | |
Cooling Towers Fluid Coolers Rental Cooling Evaporative Condensers Cooling Towers | |
| deliver systems and water saving strategies to help achieve your sustainable building goals. | |
lers | Rental Cooling Evaporative Condensers Cooling Towers Fluid Coolers Rental Coolin |
Cooling Towers
Marley NC® Class Cooling Tower—The flagship product of the Marley Package line comes with the most available options. Factory assembly is standard and the NC is available in galvanized or stainless steel. Cells available from 99 to 1,300 tons per cell. Factory Mutual Approval standard on most models and available on all models. CTI Certified.
Marley QuadraFlow® Cooling Tower— Induced-draft, low profile design. These fiberglass and stainless steel towers are field assembled to facilitate siting, and are available from 129 to 1,047 tons per cell. CTI Certified.
Marley MD Cooling Tower—Counterflow,induced-draft design requires less plan area than crossflow towers. Factory assembly is standard and the MD is available in galvanized or stainless steel. Tower available from 165 to 500 tons per cell. Five-year mechanical equipment warranty. CTI Certified.
Marley Aquatower® Cooling Tower— Reliable performance has made this design the industry standard for more than 50 years. Available in galvanized or stainless steel. Capacities from 8 to 126 tons per cell. CTI Certified.
Marley AV Cooling Tower—Singleflow,induced-draft crossflow design offers pump and fan energy savings in a small footprint installation. Factory assembly is standard and the AV is available in galvanized or stainless steel. Tower cells available from 117 to 390 tons per cell. CTI Certified.
Marley NC® Fiberglass Cooling Tower— Fiberglass, field-erected, crossflow cooling tower designed to serve air conditioning and refrigeration systems as well as light or medium industrial process loads on clean water. Structure is available available in galvanized or stainless steel. Cells available from 105 to 942 tons per cell. CTI Certified. Not available in the US, Canada or Europe.