CHIMNEY CAP INSTALLATION

9.Install the chimney cap by placing the cap into matching parts of the last chimney section. Then punch or drill 1/8 inch diameter holes in the inlet air duct (chimney pipe) where specified on the brackets and fasten it down with the No. 8 screws provided. Do not penetrate the inner stainless steel pipe while installing the screws.

10.Check all the parts of the fireplace, chimney and chimney termination cap to assure that no parts have

been damaged or bent during installation and that all parts have been installed properly.

NOTE: The metal used for the chimney cap has a rust protective coating but the cut edges of the parts are not protected. To prevent rusting and rust staining of nearby structures, exposed parts of the chimney and chimney cap should be detergent washed and painted with a galvanized primer paint.

The preinstalled chimney sections should be no more than 13 inches below the top of the chase. The installation should be planned so that either a two-foot or three-foot chimney section will be used for the top section. This is necessary to ensure complete engagement of the inlet air telescope and chimney cap into the top section.

1.Extend the chimney sections until the top of the chimney is not more than 13 inches below the top of the chase.

2.Center the hole in the chase cover over the chimney. The chase cover overhang should be lanced, formed over the chase and secured with nails. This prevents water from seeping under the chase cover. If two or more chase covers are to be used on the same chase, they should be soldered together to form two watertight seams.

3.Place the outer telescope inside the hole in the chase cover and lower it down into the mating pipe of the chimney until the support brackets on the telescope section rest on the flange of the chase cover.

4.Bend the tab with a hole on each bracket outward and secure the telecope to the flashing, using the tabs provided.

5.Once the telescope is secured, place the rain shield over the top of the telescope pipe assembly. The rain shield will be supported by the telescope brackets.

CAUTION: Be careful around electrical wires to avoid the electrical shock hazard of contacting the wires with the metal chimney components.

NOTE: When two fireplace chimneys are terminated above the same chase, the centers of the chimney caps should be at least 24 inches apart to help prevent smoke from a fireplace in use from being drawn down the chimney of a fireplace that is not in use. Additional spacing between caps or staggering the height of the caps will further lessen the likelihood of this occurring.

6.Place LCL cap assembly into position by aligning the flue telescope into the last section of flue pipe and lower it down until the 3 cap legs rest on the top edge of the outer telescope pipe. Secure legs of cap to the telescope with screws provided.

7.Check all parts of the chimney and chimney cap to assure that no parts have been damaged or bent during installation and that all parts have been installed properly.

NOTE: The metal used for the chimney and chimney cap has a rust-protective coating but the cut edges of the parts are not protected. To prevent rusting and rust staining of nearby structures, exposed parts of the chimney and chimney cap should be detergent-washed and painted with galvanized primer paint.

17

53D9042. Rev 1 03/03

Page 18
Image 18
Martin Fireplaces 53D9042 manual Chimney CAP Installation

53D9042 specifications

The Martin Fireplaces 53D9042 is a stunning addition to any home, blending advanced technology with timeless design. This model is built to offer both aesthetic appeal and functional warmth, making it an ideal choice for homeowners seeking to enhance their living spaces.

One of the standout features of the Martin Fireplaces 53D9042 is its efficient heating capabilities. With a powerful output, this fireplace can heat large areas effectively, ensuring that your home remains comfortable even during the coldest months. The unit is designed with a high-efficiency combustion system that maximizes fuel usage, minimizing heat loss and helping to reduce energy bills.

In terms of design, the 53D9042 boasts a sleek, contemporary look that fits seamlessly into modern and traditional homes alike. The glass front enhances the visual appeal, providing a mesmerizing view of the flames while allowing for easy monitoring of the fire. The clean lines and polished finish make it a stunning focal point for any room.

The advanced technology incorporated into the Martin Fireplaces 53D9042 is another notable aspect. This model is equipped with an electronic ignition system, which allows for easy start-up and convenience. The adjustable flames can be tailored to create the perfect ambiance, while the remote control functionality provides added comfort, allowing users to control the fire from across the room.

Safety features are also prioritized in the design of the 53D9042. The fireplace incorporates a safety shut-off mechanism that activates if the unit overheats, providing peace of mind to homeowners, especially those with children or pets. The air intake system is designed to ensure proper ventilation, preventing the buildup of harmful gases within the home.

Overall, the Martin Fireplaces 53D9042 represents a perfect synergy of style, technology, and performance. Its blend of functionality and design makes it a superb choice for anyone looking to invest in a high-quality heating solution. With its efficient heating output, innovative technologies, and elegant appearance, the 53D9042 is sure to enhance both the warmth and ambiance of any living space, making it a worthwhile investment for the years to come.