GAS LINE AND ELECTRICAL INSTALLATION

Turn RS-ON-OFF switch to the “ON” position.

￿If meter is reading more than 175 millivolt and the main burner does not come on, then replace control valve.

￿If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this manual to determine the cause of the low reading.

Turn RS-ON-OFF switch to the “RS ” position and wall switch to “ON”

￿If meter is reading more than 175 millivolt and the main burner does not come on, then replace control valve.

￿If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this manual to determine the cause of the low reading.

Electronic Pilot Ignition Wiring:

WARNING

Do not connect 110-120 VAC to the Remote Wall Switch. The appliance will malfunction or be destroyed.

Figure 14: Wiring Diagram for Electronic Ignition System

Remote Wall Switch

Position the wall switch. Refer to Figure 14: Wiring Diagram for Electronic Ignition System. Do not extend beyond the 15 feet of wire.

Optional DC Remote Systems

These instructions supersede the section entitled “Hearth Mount” in the Millivolt hand held remote instructions supplied with the remote.

18

Page 19
Image 19
Martin Fireplaces BV4536, BV5142 Electronic Pilot Ignition Wiring, Wiring Diagram for Electronic Ignition System