Martin Fireplaces VFCS30SPV manual Electrical Wiring Milli-Volt, Operating Thermostat Sensor, page

Models: VFCS20SNV VFCS20SPV VFCS30SNV VFCS30SPV

1 32
Download 32 pages 24.59 Kb
Page 17
Image 17
ELECTRICAL WIRING (MILLI-VOLT)

 

ELECTRICAL WIRING (MILLI-VOLT)

 

 

4. Remove adhesive backing from plastic clip. Press

Valve

clip to bottom of valve. Clip thermo bulb into plastic

 

clip. See Figure 13.

 

5. Reattach faceplate or reinstall base.

6.Install knob to shaft of t-stat sensor. See Figure 13,

page 17.

Thermo clip. See Figure 13.page 17.

Bulb

Plastic Clip

Figure 13 - Clipping Thermo Bulb into
Plastic Clip.

OPERATING THERMOSTAT SENSOR

1.Follow millivolt lighting instructions on lighting plate attached to unit or in homeownerʼs manual.

2.With control knob in the “ON” position make sure the ON/OFF switch is in the “OFF” position. See Figure 16.

3.The unit is now being controlled by the thermostat sensor. The sensor will now cycle the burners on and off. You can adjust how often the unit cycles by turning the control knob on the sensor.

REMOTE

CONTROL

 

PILOT

Piezo

Ignitor Hi/Lo

Knob

Pilot

OFF

Optional

Fan

Figure 16 - Control Knob in “ON” Position and ON/OFF Switch in “OFF” Position

58D6003

17

Page 17
Image 17
Martin Fireplaces VFCS30SPV, VFCS20SPV Electrical Wiring Milli-Volt, Operating Thermostat Sensor, clip. See Figure, page