Marvel Industries 30WCM manual Installation

Models: 30WCM

1 12
Download 12 pages 26.25 Kb
Page 3
Image 3
INSTALLATION

INSTALLATION

Select Location

The proper location will ensure peak performance of your appliance. Choose a location where the unit will be out of direct sunlight and away from heat sources. Best perfor- mance will be maintained when installed within the follow- ing parameters:

Ideal Ambient Temperature Range

Built-In

65-80 degrees F

Free-Standing

65-90 degrees F

 

 

Cabinet Clearance

Ventilation is required from the bottom front section of the unit. Keep this area open and clear of any obstructions.

Electrical Plug Optional Location: Cutout shown for electrical outlet which can be located in adjacent cabinetry.

Power Supply Cord with 3-prong grounding plug

Grounding Type Wall

Receptacle

Cord may be flush with back wall

Figure 1

Electrical Connection

Use nominal 115 VAC, 60 Hz only. DO NOT USE AN

EXTENSION CORD.

Grounding Method

This product is factory equipped with a power supply cord that has a three-pronged, grounded plug. It must be plugged into a mating grounding type receptacle in accor- dance with the National Electrical Code and applicable lo- cal codes and ordinances (see Figure 1). If the circuit does

not have a grounding type receptacle, it is the responsibility

Figure 2and obligation of the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The third ground prong should not, under any circumstances, be cut or removed (see Figure 2). All U.L. listed refrigerated prod- ucts are equipped with this type of plug.

2

Page 3
Image 3