Master Bilt BEM-3-30, BEL-5-24 MODULES REQUIRED FOR 24 WIDE DOOR LINEUPS & BTU PERFORMANCE DATA

Models: BEL-2-30 BEL-3-24 BEL-3-30 BEM-5-24 BEM-2-30 BEM-5-30 BEL-6-24 BEL-4-24 BEM-3-24 BEM-4-30 BEL-5-30 BEM-6-24 BEM-3-30 BEM-4-24 BEL-4-30 BEL-5-24

1 6
Download 6 pages 25.89 Kb
Page 3
Image 3
MODULES REQUIRED FOR 24" WIDE DOOR LINEUPS & BTU PERFORMANCE DATA

MODULES REQUIRED FOR 24" WIDE DOOR LINEUPS & BTU PERFORMANCE DATA

 

MODULES REQUIRED

TOTAL OVERALL

+20°F SUCTION MIN.

-11°F SUCTION MIN.

-18°F SUCTION MIN.

 

 

 

 

 

LENGTH

BTUs (75°F STORE,

BTUs (75°F STORE,

BTUs (75°F STORE,

NO. OF

3

4

5

6

WITH ONE PAIR

55% RH, +35°F AVER-

55% RH, -3°F AVERAGE

55% RH, -12°F AVER-

DOORS

DOOR

DOOR

DOOR

DOOR

OF 2" ENDS

AGE PRODUCT TEMP.)

PRODUCT TEMP.)

AGE PRODUCT TEMP.)

3

1

 

 

 

763/8"

3750

4750

5125

4

 

1

 

 

1001/8"

4600

6150

6550

5

 

 

1

 

1237/8"

5750

7625

8300

6

 

 

 

1

1475/8"

6900

9150

9960

7

1

1

 

 

1721/2"

8050

10,675

11,620

8

 

2

 

 

1961/4"

9200

12,200

13,280

9

 

1

1

 

220"

10,350

13,725

14,940

10

 

 

2

 

2433/4"

11,500

15,250

16,600

11

 

 

1

1

2671/2"

12,650

16,775

18,260

12

 

 

 

2

2911/4"

13,800

18,300

19,920

13

 

2

1

 

3161/8"

14,950

19,825

21,580

14

 

2

 

1

3397/8"

16,100

21,350

23,240

15

 

 

3

 

3635/8"

17,250

22,875

24,900

16

 

4

 

 

3881/2"

18,400

24,400

26,560

17

 

 

1

2

4111/8"

19,550

25,925

28,220

18

 

 

 

3

4347/8"

20,700

27,450

29,880

19

 

1

3

 

4593/4"

21,850

28,975

31,540

20

 

 

4

 

4831/2"

23,000

30,500

33,200

21

1

 

 

3

5071/4"

24,150

32,025

34,860

22

 

1

 

3

531"

25,300

33,550

36,520

23

 

 

1

3

5543/4"

26,450

35,075

38,180

24

 

 

 

4

5781/2"

27,600

36,600

39,840

25

 

 

5

 

6033/8"

28,750

38,125

41,500

MODULES REQUIRED FOR 30" WIDE DOOR LINEUPS & BTU PERFORMANCE DATA

 

MODULES REQUIRED

TOTAL OVERALL

+20°F SUCTION MIN.

-11°F SUCTION MIN.

-18°F SUCTION MIN.

 

 

 

 

 

LENGTH

BTUs (75°F STORE,

BTUs (75°F STORE,

BTUs (75°F STORE,

NO. OF

2

3

4

5

WITH ONE PAIR

55% RH, +35°F AVER-

55% RH, -3°F AVERAGE

55% RH, -12°F AVER-

DOORS

DOOR

DOOR

DOOR

DOOR

OF 2" ENDS

AGE PRODUCT TEMP.)

PRODUCT TEMP.)

AGE PRODUCT TEMP.)

2

1

 

 

 

66"

2800

3300

3550

3

 

1

 

 

961/2"

3750

4750

5125

4

 

 

1

 

1267/8"

4600

6150

6550

5

 

 

 

1

1573/8"

5750

7625

8300

6

 

2

 

 

189"

6900

9150

9960

7

1

 

 

1

2193/8"

8050

10,675

11,620

8

 

1

 

1

2497/8"

9200

12,200

13,280

9

 

 

1

1

2801/4"

10,350

13,725

14,940

10

 

 

 

2

3103/4"

11,500

15,250

16,600

11

 

2

 

1

3423/8"

12,650

16,775

18,260

12

1

 

 

2

3723/4"

13,800

18,300

19,920

13

 

1

 

2

4031/4"

14,950

19,825

21,580

14

 

 

1

2

4335/8"

16,100

21,350

23,240

15

 

 

 

3

4641/8"

17,250

22,875

24,900

16

 

2

 

2

4953/4"

18,400

24,400

26,560

17

1

 

 

3

5261/8"

19,550

25,925

28,220

18

 

1

 

3

5565/8"

20,700

27,450

29,880

19

 

 

1

3

587"

21,850

28,975

31,540

20

 

 

 

4

6171/2"

23,000

30,500

33,200

21

 

2

 

3

6491/8"

24,150

32,025

34,860

22

1

 

 

4

6791/2"

25,300

33,550

36,520

23

 

1

 

4

710"

26,450

35,075

38,180

24

 

 

1

4

7403/8"

27,600

36,600

39,840

25

 

 

 

5

7707/8"

28,750

38,125

41,500

3

Page 3
Image 3