STOPPING ENGINE

OWNER’S MANUAL

OPERATION

Continued

STOPPING ENGINE

IMPORTANT: The engine speed is preset. The throttle is locked in preset position. Do not adjust throttle.

Follow the steps below to stop engine.

1.Remove all electrical loads from gen- erator (see Disconnecting Electrical Loads, page 12). Remove electrical loads one at a time.

2.Let engine run for two or three min- utes after removing electrical loads. This lets engine cool slightly.

3.Turn engine switch to the OFF posi- tion (see Figure 18).

 

HONDA

 

 

ON

 

OFF

START

Engine

ENGINE SW

 

BREAKER

 

CIRCUIT

Switch

ON/push OFF

Figure 18 - Engine Switch

MAINTENANCE AND REPAIRS

MAINTENANCE AND REPAIRS WARNING: Only a qualified electrical service person should service and repair the alternator on this generator. Use only fac- tory approved replacement parts.

 CAUTION: Shut off generator before performing maintenance. CAUTION: The engine speed is preset. The throttle is locked in preset position. Do not adjust throttle. Preset position lets en- gine run at 3600 RPM under load. The engine must maintain 3600 RPM for generator to create cor- rect voltage. Running engine at lower speeds will damage gen- erator and powered items.

STORAGE CAUTION: Shut off generator before performing maintenance.

IMPORTANT: Keep generator level when servicing. Never turn generator upside down or stand it on end to service.

Note: We supply the engine owner’s manual with generator. Refer to that manual for questions concerning engine maintenance and repairs.

Non-engine parts require little maintenance. Keep generator clean. Use a damp cloth to clean outside surfaces. Never use water to clean generator. Water can cause damage to internal parts. Use vacuum to clean air inlet and outlet louvers of alternator.

STORAGE

Manual background WARNING: Remove all fuel from fuel tank before storing gen- erator. Store fuel in approved con- tainer. Store fuel in a well-vented area free of open flames or sparks.

Manual background WARNING: The muffler be- comes very hot during operation. The muffler remains hot for a while after shutdown. Let engine cool before storing.

IMPORTANT: Keep generator level while in storage. Never store generator upside down or standing on end.

Note: We supply the engine owner’s manual with generator. Refer to that manual for questions concerning engine storage.

Use a fuel additive, such as STA-BIL®or an equivalent, when storing generator with fuel in fuel tank. This will minimize fuel gum deposits from forming in engine.

Cover and store generator in a clean, dry place. Do not expose generator to extreme high or low temperatures during storage.