PORTABLE GASOLINE GENERATORS
GENERATOR
GROUNDING
WARNING: You must prop- erly
Grounding generator helps prevent electric shock from a ground fault condition. Follow these steps to ground your generator:
1. | Locate ground bolt on generator hous- |
| ing (see Figure 11). |
2. | Loosen SEM nut on ground bolt. Note: |
| Do not remove SEM nut from bolt. |
3. | Attach a spade connector to the end of |
| a |
4. | Attach spade connector to ground bolt |
| between flat washer and SEM nut (see |
| Detail A in Figure 11). |
You must supply the ground wire and ground- ing point. These do not come with generator. Follow the National Electrical Code and all state and local codes. Consult your power company or a licensed electrician.
WARNING: For a grounding point, do not use metal pipe be- ing used to carry combustible materials or gases.
Flat Washer
SEMS Nut
Ground Bolt
Spade
Connector
HO
Detail A
STANDBY INSTALLATION TO HOME OR BUILDING
WARNING: Have standby in- stallation performed by a skilled, licensed electrician. Do not let anyone else wire into a utility circuit. Personal injury, equip- ment damage, or damage to home could occur.
IMPORTANT: This generator will not power your entire home. Most home utility electric service is more than 60 amps. This will exceed generator output. Only power needed items during a power outage. Make sure total wattage of electrical load does not exceed rated wattage of generator.
You may need to use this generator as a standby power source. During a power out- age, the generator will power selected items in a building. Have generator and additional
5. | Drive grounding point into ground. |
| Note: Grounding point can be a stake, |
| grounding rod, or pipe. Grounding |
| point should be copper or brass. |
6. | Attach ground wire to grounding point. |
E | FUEL |
| F |
Ground
Wire
Copper or Brass |
|
Grounding Point | Alternator |
| 120V | |
120VI |
|
|
GFC |
|
|
| 0/2 | 40V |
| OCK | |
TER | 12ISTL | |
TW |
| |
R ME |
|
|
HOU |
|
|
|
| |
AUTO |
|
|
ON |
| SET |
OFF |
| |
| RE | |
| T |
|
| RESE |
|
RESET |
|
|
wiring installed by a skilled, licensed elec- trician. This is not a
WARNING: The electrician must install a
Figure 11 - Grounding Generator
8 | 115407 |