1. LEVELING

2. STABILITY

FOOT

Set all leveling feet at same height. A minimum of Y2'clearance between the machine and the floor is recommend- ed. Adjust to match the height of your dryer,

WITH HANDS

TO CHECK IF /

LEVELAND

STABLE

Place dryer in the location where it will be used. Check, by rocking dryer with hands on opposite corners, that all four (4) feet are in firm contact with the floor. If it rocks, adjust as needed.

3A. OUTSIDEWALL

3B. BASEMENTWALL

3C. FLOOR EXHAUSTING

rBASEMENTWIJNBOW

OUTSIDEWALL--

exhaust vent. Outside exhaust vent should fit over dryer vent pipe to avoid

catching lint.Tape all joints with heat duct tape.

IAttach dryer vent pipe to outside

WALL

SIDEVIEW_o

'

In basements, the exhaust can be ele- vated by installing elbows to raise the vent hood above the ground level,

ed downwardthrough the floor may be

used If not possible, the dryer may be tratedexhaustedlaterthroughinthis manualbottom.the as illus-

If space permits, a 4" dia. elbow point-

3D. INDOOREXHAUSTING

(NOT RECOMMENDED unless conditionson page 6 are met.)

._,

__

When exhausting indoors, use the

indoor exhaust kit and maintain a mini- mum clearance of 6 inches between the

rear of the dryer and any adjacent wall.

Read further instructions in this manual, Page 6.

4. ELECTRICAL CONNECTION INSTALLATIONWlTH

POWERCORD (PIGTAIL).

POWER CORD

DRYER

PLUG

RECEPTACLE

 

 

MAIN SERVICE

 

_

ENTRANCEPANEL

ATTACHMENT WALL

This appliance must be connected to a grounded metal, permanent wiring system; or an equipment - grounding conductor must be run with the cir-

cuit conductors and connected to the equipment - grounding terminal or lead on the appliance.

4

Page 4
Image 4
Maytag 53-3442 installation instructions Rbasementwijnbow