Maytag C310 Combustible Mantel, Insert, Side view of optional mantel deflector shown, Model

Models: C310

1 16
Download 16 pages 59.74 Kb
Page 7
Image 7
Model

Required Clearances

WARNING: BE ABSOLUTELY SURE THE DISTANCE BE- TWEEN THE HEATER AND THE SURFACE OF ANY COM- BUSTIBLE CONSTRUCTION IS NOT LESS THAN SHOWN ON THIS PAGE.

Model

*A

*B

*C

*D

E(1)

 

 

 

 

 

 

C310

USA-30”

USA -20”

20”

15”

8”

 

CAN-787mm

CAN-584mm

508mm

381mm

200mm

C310 with

22”

12”

20”

8”

8”

mantel

559mm

305mm

508mm

200mm

200mm

and/or side

 

 

 

 

 

shields

 

 

 

 

 

 

 

 

 

 

 

Model

F (1)

G

H

J(2)

M

 

 

 

 

 

 

C310

24”

14-1/2”

22-1/2”

5-1/4”

50-1/2”

 

610mm

368mm

572mm

133mm

1283mm

C310 with mantel

24”

14-1/2”

22-1/2”

5-1/4”

50-1/2”

and/or side

610mm

368mm

572mm

133mm

1283mm

shields

 

 

 

 

 

*Reduced clearances may be available for A, B, C and D dimensions per NFPA 211 - latest edition, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Ap- pliances (in Canada CSA B365 - latest edition). See section on “Reduction of Appliance Clearance with Specified Forms of Protection.”

**Side view of optional mantel deflector shown.

(1)Hearth extension reductions: 2” (51mm) reduction for 2” (51mm) raised hearth. (USA & Canada) 24” minimum hearth extension on all stoves as measured from the door opening of the unit (16" [406mm] minimum hearth extension on all inserts as measured from the door opening of the unit). Minimum distance of floor protection to the side = 8” (200mm). This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada.

(2)J = Maximum lintel depth without flue offset or smoke deflector.

Hearth Protection

The hearth and/or floor protection must be a thermally rated non-combustible hearth/floor protector meeting or exceeding a thermal rating of k=.84 or equivalent with a listed thickness of 3/4" (19mm) minimum in USA and Canada. The covering must extend 24” (610mm) in front of the heater and 8” (200mm) to either side (measured from door opening in the USA and measured from the side of the unit in Canada).

Maximum Mantel Depth = 9” (229 mm)

COMBUSTIBLE MANTEL

 

Top Facing / Trim

 

Side Facing Material

B

A

 

 

SIDE WALL

D

 

 

 

 

C

 

Insert

 

 

 

Hearth Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E (Canada)

 

 

 

 

E (USA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4

 

Mantel

 

 

Trim

 

 

**

 

M

9”

G

 

229mm

 

F

 

J

H

Hearth Protection

Figure 5

Notes

Facing material that projects more than 3/4” (19mm) from the wall is considered a mantel or side wall.

MINIMUM FIREPLACE OPENING 22-1/2” (572mm) High x 28-1/2” (724mm) Wide

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.