5.Placement of Glowing Embers -

8

INSTALL VERMICULITE, VOLCANIC STONE, GLOWING EMBERS AND LOGS

1.Remove the front glass enclosure panel (see Removing Glass Enclosure Panels on this page).

2.Carefully remove the old logs, embers volcanic stone and vermiculite from the firebox. Handle logs carefully to prevent breakage.

3.Install Vermiculite - Place some vermiculite on the firebox floor around the burner (the entire bag of vermiculite will NOT be used). See Figures 8 & 9. DO NOT PLACE ANY VERMICULITE ON THE BURNER. Mound up a portion of the vermiculite in front of the burner.

4.Install decorative volcanic stone - Sprinkle the decorative volcanic stone (dark colored) on top of the vermiculite (light colored) in a pleasing pattern (see Figures 8 & 9).

5.Placement of Glowing Embers -

Separate the Embers (rockwool) into pieces about the size of a quarter (see Figure 7). Keep the pieces fluffed up, not matted. Distribute these pieces over the surface of the burner, as shown in Figures 8 & 9. Do not use more than is necessary. Ensure that the main burner slots remain uncovered by the ember material.

Note: This appliance is provided with enough Glowing Embers for several applications, do not use all that is in a new bag at one time. For bestglowingeffect,replacetheembermaterial annually.

6.Placement of Logs and Twigs -

All logs that have locating notches or slots to help ensure that they are properly positioned. All top logs that rest on lower logs, do so over notches, indents or pins. Proper twig placement is critical to prevent sooting. Twigs shouldbeplacedinthegapsbetweentheflame peaks and should be positioned so they do not impinge the flames.

LMDV-3328 & LMDV-3530 - Install as Follows

Carefully position the ceramic fiber logs and twigs over the burner as shown in Figure 8. Logs should be placed in the order shown and per the following instructions.

1. Place the rear log (A) as shown. Position the 2 notches on the bottom of the log over the 2 corresponding locating brackets against the back wall of firebox.

2. Place the left log (B) as shown. The notch on the bottom of the log should fit over the corresponding locating bracket.

3. Place the right log (E) as shown. The hole on the back of the log should fit over the corresponding pin on the rear log (A). Make sure that the log is positioned so it aligns to the sides of the gas ports on the corner of the burner.

4. Place the left center log (C) as shown. The forked end of the log fits into the cor- responding notch on rear log (A). The slot on the other end (bottom) of log fits over the corresponding locating bracket on the sub-floor.

5. Place the right center log (D) as shown. One end of the log fits into the corresponding indent on the right log (E). The slot on the other end (bottom) of log fits over the corresponding locating bracket on the sub- floor.

LMDV-4035 - Install as Follows

Carefully position the ceramic fiber logs and twigs over the burner as shown in Figure 9. Logs should be placed in the order shown and per the following instructions.

1.Position the center log (C) onto the 2 cor- responding location pins on the burner.

2. Place the rear log (A) as shown. Position the 2 notches on the bottom of the log over the 2 corresponding locating brackets against the back wall of firebox.

3. Place the left log (B) as shown. The notch on the bottom of the log should fit over the corresponding locating bracket.

4. Place the right log (E) as shown. The notch on the bottom of the log should fit over the corresponding locating bracket. Make sure that the log is positioned so it aligns to the sides of the gas ports on the corner of the burner.

5. Place the center front log (D) as shown. The slot in the bottom of the log fits over the corresponding location bracket on the sub-floor.

WARNING

DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

6.Placement of Logs and Twigs - WARNING

The size and position of the log set was engineered to give the appliance a safe, reliable and attractive flame pattern. Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion, soot- ing, and poor flame quality.

LMDV-4035 - Install as Follows WARNING

This appliance is not designed to burn wood. Any attempt to do so could cause irreparable damage to appliance and prove hazardous to your safety.

Glowing Embers WARNING

If logs are not installed according totheloginstallationinstructions, flameimpingementandimproper combustioncouldoccurandresult in soot and/or excessive produc- tion of carbon monoxide (CO), a colorless, odorless, toxic gas.

Glowing Embers

Separate into Quarter

Size (separate) Pieces

Bag of Glowing

Embers (rockwool)

Figure 7

REFERENCE

Firebox Accessories / Parts

Cat. No.

Model No.

Description

 

 

 

88L53

FGE

Bag of Glowing Embers

 

 

(1 oz. rockwool)

 

 

 

42363

 

Vermiculite, Bag (2 liters)

 

 

 

80L42

FDVS

Bag of Decorative

Volcanic Stone

 

 

 

 

 

Table 8

Page 8
Image 8
Maytag LMDV-35 SERIES, LMDV-40 SERIES manual Figure, Table, Placement of Glowing Embers, Placement of Logs and Twigs