BURNER ADJUSTMENTS

BURNER ADJUSTMENTS

(QUALIFIED TECHNICIANS ONLY)

Flame Appearance and sooting

Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame. When the appliance is first lit, the entire flame may be blue and will gradually turn yellowish-orange during the first

15minutes of operation. If after a short period the flame stays lowered blue, or if the flame is orange with evidence of sooting (black tip), the air shutter opening may need to be adjusted.

If the air shutter openings closed too far, sooting may develop. Sooting is indicated by black puffs developing at the tips of very long orange flames. Sooting results in black deposits forming on the logs, appliance inside surfaces and on exterior surfaces adjacent to the vent termination. Soot- ing is caused by incomplete combustion in the flames and lack of combustion air entering the air shutter opening. To achieve a warm yellow- ish-orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes.

Air Shutter Adjustment Guidelines

If there is smoke or soot present, first check the log set positioning to ensure that the flames are not impinging on any of the logs. If the log set is properly positioned and a sooting condition still exists, then the air shutter opening should be increased.

The more offsets in the vent system, the larger the air shutter opening will need to be.

An appliance operated with the air shutter opened too far, may have flames that appear blue and transparent. These weak, blue and transparent flames are termed anemic.

Propane models may exhibit flames which candle or appear stringy. If this is present and persists, adjust the air shutter to a more open position, then operate the appliance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty.

The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation.

Air Shutter Adjustment Guidelines:

Amount of

Flame

Air Shutter

Primary Air

Color

Adjustment

 

 

 

 

 

 

 

If air shutter is

Flame will

Air shutter

closed too far

be orange

gap should be

 

 

 

 

 

 

increased

 

 

 

 

 

 

If air shutter is

Flame will

Air shutter

open too far

be blue

gap should be

 

 

 

 

 

 

decreased

 

 

 

 

 

 

Figure 10 - Burner Flame Appearance Model LMDV-3328 & LMDV-3530

Figure 11 - Burner Flame Appearance Model LMDV-4035

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.