Component Testing Procedures

!WARNING

To avoid electrical shock, personal injury, or death: disconnect power supply before servicing, unless testing requires it.

SETTING

APPROXIMATE SECONDS

TIME

ON

OFF

LOW

3

20

MED

5

7

HIGH

Constant

0

4.Replace the control if it is not cycling properly. Calibration is not possible.

The surface units and controls offer infinite heat settings. Controls must be pushed down before turning. All surface controls are marked on the control panel for their respective heating element. Infinite switch contacts

L1 - H1 and L2 - H2 provide power to the surface elements.

Resistance / Continuity

A malfunction in the internal switching may fuse the cycling contacts. This causes the heating element to operate at full power, at all control settings, while cycling on element limiter.

Check continuity on infinite switch contacts by using the following steps.

1.Turn off power to cooktop.

2.See “Disassembly Procedure“ to access switch.

3.Remove all control panel knobs. Remove control panel assembly.

4.Remove switch mounting bracket screws. Lift bracket upward. The location of the switch terminals is shown below.

TOP

P L1 L2

H1 H2

Infinite Switch Contacts

5.Remove wiring from switch.

6.Set ohmmeter on R x 1K scale. Check for continuity according to the following chart.

 

 

 

Dial Position

 

Contacts

OFF

 

LO-MED

 

HI

L1

– L2

O

 

E

 

X

L1

– P

O

 

X

 

X

L1

– H1

O

 

X

 

X

L1

– H2

O

 

X – C

 

X

H1 – H2

X

 

E

 

X

O−Open X−Closed C−Cycles

E−Indicates resistance across internal heater

7.If any contacts fail continuity test, replace infinite switch.

NOTE: During actual surface element operation, contacts L2 - H2 will cycle to maintain the correct heat setting. Contacts L1 - P provide power to the surface element indicator light.

P1

L1H1

H2

L2

Infinite Switch Schematic

If the infinite switch contacts are good and the element does not heat, check for voltage at the heating element terminal plug block. A voltage of 240 V should be indicated. If no voltage is indicated, check for a broken wire or loose connection.

Surface Element (Dual Infinite Switch)

The surface units and controls offer infinite heat settings. Controls must be pushed down before turning. All surface controls are marked on the control panel for their respective heating unit. Indicator ON light uses contacts 2 – 5, which must be closed before contacts 2 – 3 when using the small burner. Also contacts 2 – 5 and 3 – 4 must be closed before contacts 2 – 3, when using the small and large burner. Infinite switch contacts 2 - 3 and 3 - 4 provide power to the surface elements.

Check continuity on infinite switch contacts by using the following steps.

1.Turn off power to cooktop.

2.See “Disassembly Procedures” to access switch.