Advanced Controller setup procedure

Advanced Controller

(Model MWF4300AWS)

Advanced Controller setup procedure

 

 

 

 

 

 

 

Advanced Controller

 

1. Modes: Use ‘next’ button to toggle through modes.

 

 

 

 

Use with waters

 

2. Manual flush: Press ‘next’ until ‘manual’ is flashing. Press ’manual flush’

 

 

having turbidity up

 

 

and hold. If held for longer than 10 seconds, drain valve remains open. Toggle

 

 

to 5.0NTU,

 

 

drain valve closed by pressing ‘manual flush’ once.

 

 

 

 

Has two output

 

3. Setting time of day: Press ‘next’ until ‘set time’ appears. Press ‘enter’. Use

 

 

terminals and

 

 

up/down arrows to set time of day. Press ‘enter’ to set.

 

 

 

controls the

 

4. Set time of flush: Press ‘next’ until ‘start time’ appears. Press ‘enter’. Use

 

 

automated drain

 

 

up/down arrows to set time of flush. Press ‘enter’ to set.

 

 

 

and inlet valve.

 

5. Setting program choice: Press ‘next’ until ‘program’ appears. Press ‘enter’.

 

 

 

 

 

 

Use up/down arrows to select program choice. Press ‘enter’ to set.

 

 

 

 

 

 

 

(See Table 6 for programming choices.)

 

 

 

 

 

Table 4-Advanced Controller

Setup Procedure

 

 

 

 

 

 

 

Choosing a Controller Program

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Base Controller

 

 

 

 

 

Controller-

Recommended

 

Source water

Daily household

 

No.

No.

 

Flush water used

Program

 

household

 

turbidity

water consumption

 

Flushes

System

 

per day

 

 

occupancy

 

(NTU)

 

 

per cycle

drains

 

(flow at

 

 

(persons)

 

 

 

 

 

per cycle

 

7USGAL/min)

 

 

 

 

 

 

 

 

 

 

Program 1

Up to 4

 

<0.5

300Usgal/d

 

2

--

 

14USgal/d (53L/d)

 

 

 

 

 

 

(1135L/d)

 

 

 

 

 

 

Program 2

Up to 4

 

<0.5Peaks to

300Usgal/d

 

3

--

 

21USgal/d (80L/d)

 

 

 

 

 

1.0NTU, <5%

(1135L/d)

 

 

 

 

 

 

 

 

 

 

 

of time

 

 

 

 

 

 

 

Program 3

Up to 6

 

<0.5 Peaks to

400Usgal/d

 

4

--

 

28USgal/d

 

 

 

 

 

1.0NTU, <5%

(1510L/d)

 

 

 

 

(106L/d)

 

 

 

 

 

of time

 

 

 

 

 

 

 

Table 5-MWF4100AWS and MWF4200AWS Controller Program Selection

MAYTAG Whole Home Water Filtration System Owners Manual MA1-5

November 2003

23

Page 23
Image 23