Maytag mwf4100aws Troubleshooting, Section of, Problem/Situation, Correction/Action, System

Models: mwf4100aws

1 42
Download 42 pages 47.3 Kb
Page 37
Image 37

Troubleshooting

The following section will help diagnose some of the problems that might occur with the MAYTAG Whole Home Water Filtration System. This guide is provided for information purposes only. Call your MAYTAG Customer Care for assistance if there are any concerns with the MAYTAG Whole Home Water Filtration System.

Section of

Problem/Situation

Correction/Action

System

 

 

General

A part is missing.

Most standard hardware parts are available at the

 

 

local hardware store or call MAYTAG Customer

 

 

Care for a MAYTAG Whole Home Water

 

 

Filtration System replacement part.

 

System leaks water.

Cap is not properly tightened.

 

 

O-ring is not clean or intact.

 

 

O-ring is not in place.

 

 

Connections are not tight.

 

 

Connections were too tight and part broke.

 

 

Water is not adequately drained from System prior

 

 

to removing cap.

 

 

Teflon tape not used on thread.

 

 

 

Checking

Pressure is too high.

Release some of the pressure until the desired

Backpulse Tank

 

pressure is reached.

Pressure *(Must

 

 

relieve water

 

 

pressure from

 

 

System before

 

 

checking backpulse

 

 

tank.)

 

 

 

The pressure is too low.

Add more pressure using a compressor or hand

 

 

pump. Check the pressure again the next day. If

 

 

the pressure drops call MAYTAG Customer Care.

 

 

 

Connecting

Threads are cross-threaded.

Replace the parts if possible. Add more Teflon tape

Piping

 

and slowly thread the two parts together to attempt

Assemblies

 

to fix the problem.

 

A leak results.

Tighten connection.

 

 

Loosen connection that is too tight.

 

 

No Teflon tape was used, call MAYTAG Customer

 

 

Care to reinstall part using Teflon tape.

 

 

 

Air Vent

Water spouts from top.

Air relief port is not capped.

 

 

Air vent is faulty.

 

No water is flowing through

Black air relief port cap must be loosened to 1 ½

 

System.

turns (to open).

 

 

 

Removal of Cap

Can not remove cap.

System may be pressurized. Turn off inlet ball

 

 

valve and drain System using controller.

 

 

No cap wrench – call MAYTAG Customer Care.

 

 

 

External

Does not drain fast enough.

Press and hold the red button on the top of the

Prefilter

 

housing to allow air to enter the housing and drain

 

 

more quickly.

MAYTAG Whole Home Water Filtration System Owners Manual MA1-5

November 2003

37

Page 37
Image 37
Maytag mwf4100aws owner manual Troubleshooting, Section of, Problem/Situation, Correction/Action, System