Before You Call

Before You Call

Check these points if your refrigerator...

 

 

• temperature control turned to “Off”

 

Won’t Run

• power cord not plugged in

 

• no power at the electrical outlet

 

 

• circuit breaker tripped or the house fuse blown

 

 

• refrigerator is in automatic defrost

 

 

 

 

 

• today’s refrigerators are larger and run colder, which requires more running time to

 

 

provide more stable temperatures

 

Runs too long/too frequently

• prolonged door openings

 

• base grille blocked

 

 

• too many door openings

 

 

• door not sealing (due to a package or a container holding door open)

 

Noisy operation

• cabinet not level

 

• weak floor

 

 

 

Odor in cabinet

• odor producing foods should be covered or wrapped

 

• interior needs cleaning

 

 

 

Warm air from cabinet bottom

• normal air flow for condenser circulation

 

Cabinet Vibrates

• cabinet not level

 

• weak floor

 

 

 

 

• hot, humid weather

 

Moisture on inside cabinet walls

• frequent or prolonged door openings

 

 

• door not closed properly

 

Excessive moisture in crisper

• food not wrapped properly

 

• hot, humid weather

 

 

 

Cabinet light not working

• bulb burned out

 

 

• no power at the outlet

 

Sizzling sound in freezer

• a normal sound caused by defrost water dripping on defrost mechanism

 

Visible glow in the freezer vents

• appearance of a red glow or reflection is normal during the defrost cycle

 

 

 

 

Freezer not freezing properly

• products with high sugar content may not harden completely when frozen (ice

 

cream, concentrated juice, etc.)

 

 

• adjust freezer control to a colder setting

 

Ice cubes evaporate

• cold air moving over the ice cubes causes shrinkage, especially with limited usage.

 

 

This is normal.

 

 

• stop arm in OFF (up) position

 

Automatic ice maker not operating

• water supply turned off

 

• water pressure too low

 

 

 

 

• freezer too warm

 

Front cabinet surface

• special design to limit condensation during periods of high humidity

 

warm to the touch

 

 

 

 

 

 

Ice dispenser not operating

• ice jam in the dispenser

 

• ice maker not operating

 

 

• lock switch on

 

Water dispenser not operating

• water supply turned off

 

• water pressure too low

 

 

• lock switch on (see pg. 7)

 

 

 