BURNER FLAME CHECK
Adjust flame height using brass valves. Rotate air control shutter
BURNER
ORANGE
to achieve mostly blue flame. The air control shutter mounted on the front of burner helps to control the amount of air that mixes with the LP gas. A blue flame with little or no yellow flame indicates a proper air/gas mixture and provides the best heat. Adjust the air control shutter until the desired flame is achieved.
FLAME BLUE
CORRECT INCORRECT
NOTE: Make sure the male fitting on hose is screwed into the burner/air shutter and tightened securely. Do not
HINT: Before lighting, turn air control shutter on the burner to an almost closed position. This increases the gas portion of the air/gas mixture and makes the burner easier to light. After lighting, turn air control shutter to an open position to achieve a better flame.
When lighting for the first time, you will smell paint burning at the top of the cooker for a few minutes...
This is normal.
If burner flame does NOT ignite immediately, or is accidentally extinguished, turn LP Gas Cylinder Valve clockwise to OFF. Then turn regulator brass valves clockwise to OFF position.
Wait 5 minutes for gas to evacuate before
If the burner does not light within the first few attempts, there is a problem with the gas supply.
Turn off the gas at the cylinder and regulator. DO NOT attempt to operate the cooker until the problem is found and corrected. Refer to Troubleshooting on Pages 26 - 27.
HOW TO REIGNITE BURNER
Follow steps
a slick surface. Use caution not to bump the cooker or cooking vessel when
TURNING OFF COOKER AND DISCONNECTING HOSE
NOTE: Turn off LP gas cylinder valve first to prevent gas from being left in the regulator hose system under pressure.
1.Turn OFF the LP gas cylinder valve clockwise until it stops.
2.Turn brass valves to the OFF position, clockwise until they stop.
3.To disconnect Regulator Hose Assembly, turn the large coupling nut
|
|
|
|
| E |
|
|
|
|
| S |
O |
|
|
| W | I |
|
| K |
| ||
F |
|
|
| ||
| F | C |
|
| |
|
| - CLO |
|
|
|
1
Turn OFF
LP Cylinder.
Close Valve Fully
O |
|
|
| S | E |
F |
|
|
|
| |
|
| I |
| ||
F | - |
| W |
|
|
| K |
|
| ||
|
| CLOC |
|
|
|
2
Turn OFF Regulator. Close Valve Fully
3
Disconnect Regulator
Turn
The LP gas cylinder valve should always be in the OFF or closed position when the cooker is not in use.