Base Grille Water Filtration System

Model P2WG2L/P2RFWG2 Capacity 200 Gallons (757 Liters)

Model P2WG2/P2RFWG2 Capacity 200 Gallons (757 Liters)

System tested and certified by NSF International against NSF/ANSI

Standard 42 for the reduction of Chlorine Taste and Odor, Particulate

Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead,

Mercury, Benzene, Toxaphene, and O-dichlorobenzene.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50% reduction

1.909 mg/L

2.0 mg/L ± 10%

0.05 mg/L

<0.05 mg/L

>97.4

>97.4

Particulate Class I*

85% reduction

9700000 #/mL

At least 10,000 particles/mL

2600 #/mL**

62000 #/mL

>97.6

>99.4

 

 

 

 

 

 

 

 

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.010 mg/L

143.33 ug/L

0.15 mg/L ± 10%

1.0 ug/L

1.0 ug/L

>99.3

>99.3

Lead: @ pH 8.5

0.010 mg/L

140 ug/L

0.15 mg/L ± 10%

1.0 ug/L

1.0 ug/L

>99.3

99.3

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

0.002 mg/L

0.0058 mg/L

0.006 mg/L ± 10%

0.3 ug/L

0.0002 mg/L

>96.5

96.5

Mercury: @ pH 8.5

0.002 mg/L

0.00646 mg/L

0.006 mg/L ± 10%

1.4 ug/L

0.0004 mg/L

76.3

88.1

 

 

 

 

 

 

 

 

Benzene

0.005 mg/L

0.015 mg/L

0.015 mg/L ± 10%

0.5 ug/L

0.0005 mg/L

>96.5

>96.5

 

 

 

 

 

 

 

 

O-Dichlorobenzene

0.6 mg/L

1.83333 mg/L

1.8 mg/L ± 10%

4.8 ug/L

0.014 mg/L

99.7

99.9

 

 

 

 

 

 

 

 

Toxaphene

0.003 mg/L

0.016 mg/L

0.015 mg/L ± 10%

1 ug/L

0.001 mg/L

>93.2

>93.2

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

Use replacement filter P2RFWG2, part #4396841.

2008 suggested retail price of $39.99 U.S.A./$54.95 Canada. Prices are subject to change without notice.

Model P2WG2L/P2WG2: Style 1 – When the filter indicator reads 10%, order a new filter. When the indicator reads 0%, it is recommended that you replace the filter.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Refer to the “Warranty” section for the Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Style 2 – When the filter indicator changes from green to yellow, order a new filter. When the indicator changes from yellow to red, it is recommended that you replace the filter.

Style 3 – When the water filter status display changes from “GOOD” to “ORDER,” order a new filter. When the filter indicator reads “REPLACE,” it is recommended that you replace the filter.

Style 4 – Press FILTER to check the status of your water filter. If the filter indicator light is yellow, order a new filter. If the filter indicator light is red, it is recommended that you replace the filter.

Change the water filter cartridge every 6 months. If the water flow to the water dispenser or ice maker decreases noticeably before 6 months have passed, replace the water filter cartridge more often.

These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 37.8°C)

Service Flow Rate

0.85 gpm (3.2 Lpm) @ 60 psi

*Class I particle size: >0.5 um to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. ® NSF is a registered trademark of NSF International.

15

Page 15
Image 15
Maytag W10213157A, W10213158A installation instructions Base Grille Water Filtration System