Maytag W10260037A, W10267625A - SP Troubleshooting, Changing the Drum Light, Dryer Operation

Models: W10260037A W10267625A - SP

1 32
Download 32 pages 51.1 Kb
Page 12
Image 12

Changing the Drum Light

The dryer light automatically turns on inside the dryer drum when you open the door.

To change the drum light

1. Unplug dryer or disconnect power.

2. Open the dryer door. Locate the light bulb cover on the back wall of the dryer. Remove the screw located in the lower right corner of the cover. Remove the cover.

3. Turn bulb counterclockwise. Replace the bulb with a 10-watt appliance bulb only. Replace the cover and secure with the screw.

4. Plug in dryer or reconnect power.

TROUBLESHOOTING

First try the solutions suggested here or visit our website and reference FAQs (Frequently Asked Questions)

to possibly avoid the cost of a service call...

In U.S.A. www.maytag.com/help - In Canada www.maytag.ca

Dryer Operation

Dryer will not run

Has a household fuse blown, or has a circuit breaker tripped? There may be 2 household fuses or circuit breakers for the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician.

Is the correct power supply available?

Electric dryers require 240-volt power supply. Check with a qualified electrician.

Was a regular fuse used? Use a time-delay fuse.

Is the dryer door firmly closed?

Was the Start/Pause button firmly pressed?

Large loads may require pressing and holding the Start/Pause button for 2-5 seconds.

No heat

Has a household fuse blown, or has a circuit breaker tripped? The drum may be turning, but you may not have heat. Electric dryers use 2 household fuses or circuit breakers. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician.

Is the valve open on the gas supply line on gas models?

Unusual sounds

Has the dryer had a period of non-use?

If the dryer hasn’t been used for a while, there may be a thumping sound during the first few minutes of operation.

Is a coin, button, or paper clip caught between the drum and front or rear of the dryer?

Check the front and rear edges of the drum for small objects. Clean out pockets before laundering.

Is it a gas dryer?

The gas valve clicking is a normal operating sound.

Are the four legs installed, and is the dryer level front to back and side to side?

The dryer may vibrate if not properly installed. See the Installation Instructions.

Is the clothing knotted or balled up?

When balled up, the load will bounce, causing the dryer to vibrate. Separate the load items and restart the dryer.

Dryer displaying code message

“PF” (power failure), check the following:

Was the drying cycle interrupted by a power failure? Depending on the length of the power outage, you may be able to resume the cycle by simply pressing START/PAUSE; otherwise, press POWER/CANCEL and then start a new drying cycle.

“F” Variable (F1, F2, F20, etc.) service codes: Call for service.

“L2” Diagnostic Code (low or no line voltage condition):

The drum will turn, but there may be a problem with your home power supply keeping the dryer's heater from turning on. The dryer will continue to run when this diagnostic code is present. Press any key to clear the code from the display and return to the estimated time remaining.

Try the following:

Check to see if a household fuse has blown or circuit breaker has tripped. Electric dryers use two household fuses or breakers. Replace the fuse or reset the circuit breaker.

In the U.S.A. - Confirm the power cord is properly installed. Refer to “Electrical Connection” for details.

Select a Timed Cycle, and restart the dryer.

If the message persists, consult a qualified electrician.

“AF” (low airflow condition):

The dryer will continue to run when this diagnostic code is present. Press any key to clear the code from the display and return to the estimated time remaining.

Try the following: Clean lint screen.

Check to see if the vent run from the dryer to the wall is crushed or kinked.

Confirm the vent run from the dryer to the wall is free of lint and debris.

Confirm the exterior vent exhaust hood is free of lint and debris.

Confirm your vent system falls within the recommended run length and number of elbows for the type of vent you are using. Refer to “Plan Vent System” in the Installation Instructions for details.

Select a Timed Cycle, and restart the dryer.

If the message persists, have your entire home venting run cleaned.

12

Page 12
Image 12
Maytag W10260037A, W10267625A - SP quick start Troubleshooting, Changing the Drum Light, Dryer Operation