How to Operate in Two Channel or Subwoofer Mode
How to Operate in Two Channel Mode
In the Two Channel Mode, Channels 1 and 2, and Channels 3 and 4 operate in bridged configuration as a pair of full frequency range 200 watt amplifiers. A typical application is use of a more powerful amplifier for stereo reproduction. Refer to figures 7 and 8.
Power
The MCC204 will turn On or Off when the Control Center turns On or Off.
Note: There must be an Amp ON connection between the MCC204 and the signal source unit in order for the amplifier power turn On and Off to function.
Input Source
Set the Channel
Sensitivity Controls
The Sensitivity Controls 1 and 3 allow the setting of input level of both bridged pairs of amplifier channels to provide an ideal match for the signal source being used.
Mode
Set both the Channel
Crossover
Set the CROSSOVER Switches to the OUT position since both bridged channels are operating at full frequency range.
How to Operate in Subwoofer Mode
In the Sub Woofer Mode, Channels 1 and 2 operate as in- dependent 50 watt amplifiers, driving two midrange and high frequency or full range speakers. Channels 3 and 4 operate in Bridged Mode as a single
.
Power
The MCC204 will turn On or Off when the Control Center turns On or Off.
Note: There must be an Amp ON connection between the MCC204 and the signal source unit in order for the amplifier power turn On and Off to function.
Input Source
Set the Channel
Sensitivity Controls
The Sensitivity Controls allow setting the input level of Amplifier Channels 1, 2 and 3 to provide an ideal match for the signal source being used. Sensitivity Control 3 ad- justs the subwoofer level balance and Sensitivity Control 4 has no effect.
Output Mode
Set the Channels
Crossover
Set the Channel
15