Mellerware VAC20002000W specifications Key points, Replace the motor filter

Models: VAC20002000W

1 6
Download 6 pages 46.29 Kb
Page 5
Image 5
Key points:

(Fig. 5)

Use the button on

 

 

the handle

3.Remove the HEPA filter as shown in Fig. 7 and 8.

(Fig. 6)

Replace the motor filter: Move the clip on tank bottom cover

4.When cleaning the HEPA filter, use a gentle bristle brush to remove fine dust particles.

(Fig. 7)

(Fig. 8)

5.Once HEPA filter cleaning is complete, insert HEPA filter back into designated area by turn- ing clockwise until filter locks into place.

6.Insert compartment back into appliance until compartment “clicks” into place. Attach hose to applance and switch on cleaner to ensure that cleaner is working correctly.

Caution:

Do not be alarmed if over time the HEPA filter changes colour. This is normal and will not have an effect on the operation of the appliance. Should cleaning of the filter not be successful, rinse the filter in water. Once complete, allow the filter to dry naturally for 24 hours.

Key points:

Please note that the appliance is able to operate without the HEPA filter and bagless dust compart- ment, but it is not advised as this can cause the appliance to malfunction. Before using this appli- ance, always ensure that all compartments and ac-

VAC2000_IM.indd 5

cessories are inserted and attached correctly.

Caution:

The motor filter is installed behind the air outlet grid, open up the air outlet grid and it may be taken out;

To remove the motor outlet filter, remove the rear grid (as shown in Fig. 9). To replace the filter of the motor outlet filter, insert filter into designated area followed by inserting the grid into place by clicking the clips into the slots.

(Fig. 9)

Air Outlet filter

How to replace and clear the air outlet filter: The air outlet filter should be cleaned or replaced every 6-12 months of use. Please ensure to cor- rectly replace all filters before switching on the ap- pliance.

1.Ensure the appliance is switched off and that the plug is removed from the socket.

2.Open the air outlet grid.

3.Remove the filter for cleaning. Also remove any excess dust which is lying in the air outlet vent.

4.Replace the filter and insert ait outlet grid into place until grid “clicks” into slot.

Replace the motor filter:

In order to ensure the best air outlet effect, some- times you need to clear the air outlet filter.

1.Take off the air outlet grid and take out the filter.

2.Clear the air outlet filter or replace it with a new filter.