Troubleshooting

Troubleshooting

NOTE: Check all possible problems and causes before disassembling the pump.

Relieve the pressure, page 14, before checking or servicing the equipment.

Problem

Cause

Solution

 

 

 

 

 

 

Pump output low on both strokes.

Restricted air supply lines.

Clear any obstructions; be sure all shutoff

 

 

valves are open; increase pressure, but do

 

 

not exceed maximum working pressure.

 

 

 

 

Exhausted fluid supply.

Refill and reprime pump.

 

 

 

 

Clogged fluid outlet line, valves, etc.

Clear.

 

 

 

 

Worn piston u-cup or v-packings.

Replace. See Bellows Displacement Pump

 

 

manual.*

 

 

 

Pump output low on only one stroke.

Held open or worn ball check valves.

Check and repair. See Bellows Displace-

 

 

ment Pump manual.*

 

 

 

 

Worn piston u-cup or v-packings.

Replace. See Bellows Displacement Pump

 

 

manual.*

 

 

 

No output.

Improperly installed ball check valves.

Check and repair. See Bellows Displace-

 

 

ment Pump manual.*

 

 

 

Pump operates erratically.

Exhausted fluid supply.

Refill and reprime pump.

 

 

 

 

Held open or worn ball check valves.

Check and repair. See Bellows Displace-

 

 

ment Pump manual.*

 

 

 

 

Clogged suction tube or filter

Clear part(s).

 

 

 

 

Worn piston u-cup or v-packings.

Replace. See Bellows Displacement Pump

 

 

manual.*

 

 

 

 

Damaged bellows.

Replace. See Bellows Displacement Pump

 

 

manual.*

 

 

 

Material visible in the overflow chamber

Damaged bellows.

Replace. See Bellows Displacement Pump

(if equipped) or weeping from port in

 

manual.*

packing nut.

 

 

 

 

 

Pump will not operate.

Restricted air supply lines.

Clear any obstructions; be sure all shut off

 

 

valves are open; increase pressure, but do

 

 

not exceed maximum working pressure.

 

 

 

 

Exhausted fluid supply.

Refill and reprime pump.

 

 

 

 

Clogged fluid outlet line, valves, etc.

Clear.

 

 

 

 

Damaged air motor.

See NXT Air Motor manual.*

 

 

 

 

Runaway solenoid has tripped.

Retract solenoid. NXT Air Motor manual.*

 

 

 