Metabo 1600 D, P 600 GB User Responsibility, Specifications, 2General, 3Connection to Power Mains

Models: 1600 D 1600 W P 600

1 12
Download 12 pages 32.21 Kb
Page 8
Image 8
GB

GB

User Responsibility

This appliance will perform in conformity with the description contained in the instructions provided. This appliance must be checked periodically. Defective equipment (including power cable) should not be used. Parts that are broken, missing, obviously worn, distorted or contaminated, should be replaced immediately.

Should such repair become necessary, it is recommended that such repairs are carried out by qualified persons approved by metabo or its representatives. This appliance or any of its parts should not be altered or changed from standard specifications. The user of this appliance shall have the sole responsibility for any malfunction which results from improper use or unauthorized modification from standard specification, faulty maintenance, damage or improper repair by anyone other than qualified persons approved by metabo or its representatives.

1 Specifications

P 600/1600 W

P 600/1600 D

Capacity

max. 9 m3/h

max. 9 m3/h

Suction head

max. 9 m

max. 9 m

Delivery head

max. 60 m

max. 60 m

Voltage

230 V ~ 50 Hz

3~ 230 V Δ 50 Hz

 

 

3~ 400 V 50 Hz

Motor capacity

1.6 kW

1.6 kW

Motor speed

2800 min-1

2800 min-1

Protection class

IP 44

IP 44

Mains fuse

16 A

16 A

Number of impellers

2

2

Self priming

yes

yes

Motor shaft

stainless steel

stainless steel

Suction port size

1 1/2"

1 1/2"

Discharge port size

1"

1"

Stock-no.

025 006 0009

025 006 0017

2General

Please read these instructions carefully before operating this centrifugal pump. Failure to comply with the instructions provided, negligence or improper handling invalidate the manufacturer's warranty.

The self-priming centrifugal pumps P 600/1600 W and P 600/1600 D have a large delivery capacity at only minimal power consumption. They are used primarily for general water transfer and recirculation, pond and excavation draining, barrel pumping etc. Undesirable constituents like sediment, fine sand or silt are abrasive and damage the duocone seal. Use of a fine filter is recommended.

Caution: Sand/silt damage the pump's seals. Undesirable constituents like sand, silt, dirt or other solid matter in the water must be kept from entering the pump by installing a filter in the suction line.

This filter prevents damage to the pump.

Due to their high suction capacity both models have a good priming characteristic and a short priming time.

If the level difference between suction head and delivery head is more than 5 metres, use of a suction tube with a diameter larger than the diameter of the suction port is required.

3Connection to Power Mains

The metabo centrifugal pump P 600/1600 W is safety earthed and must be connected to an earthed single-phase outlet providing 230 VAC 50 Hz power. The circuit should be protected with a min. 16 A fuse.

The Elektra Beckum centrifugal pump P 600/1600 D is safety earthed and must be connected to an earthed three- phase outlet providing 400 VAC 50 Hz power. The circuit should be protected with a min. 16 A fuse.

It is recommended to operate this appliance on a residual current device (RCD) of 30 mA capacity.

Damaged power cables must be replaced by a qualified electrician or authorized service centres. Keep grade H 07 RN-F 3G 1.0 mm˝ or similar.

Operating this device with a damaged electrical cable is dangerous. Danger of personal injury!

When this device is used near swimming pools or garden ponds adhere to all relevant legislation. If in doubt consult a qualified electrician.

A defective pump should be taken out of service immediately, as water leakage may cause damages.

-Pull plug from socket if unit is not in use (holidays, weekend homes etc.).

-Children and juveniles should not operated this device.

-Use only genuine Elektra Beckum spare parts for repairs.

7

Page 8
Image 8
Metabo manual GB User Responsibility, Specifications, 2General, 3Connection to Power Mains, P 600/1600 W, P 600/1600 D

FAQ

What are the general uses of the P 600/1600 W and P 600/1600 D centrifugal pumps?

These pumps are primarily used for general water transfer and recirculation, pond and excavation draining, and barrel pumping.

What should I do if the pump is defective or damaged?

A defective appliance or any of its parts should be replaced immediately. Repairs should be carried out by qualified persons approved by Metabo or its representatives.

What is the recommended voltage and circuit protection for the P 600/1600 W and P 600/1600 D pumps?

The P 600/1600 W should be connected to a single-phase outlet providing 230 VAC 50 Hz power, protected with a min.16 A fuse. The P 600/1600 D should be connected to a three-phase outlet providing 400 VAC 50 Hz power, also protected with a min.16 A fuse.