Page 11
Image 11
Motor hums but does not start:

Ensure there is a sufficient water supply.

Make sure the float switch can move unrestricted.

Motor hums but does not start:

ξPump blocked by foreign object.  Clean pump.

Pump does not pump properly:

ξDelivery head too high.

Observe max. delivery head (see "Technical Specifications").

ξDischarge hose kinked.

Straighten discharge hose.

ξDischarge hose leaky.

Seal discharge hose, tighten screw fittings.

Pump runs very noisy:

ξPump primes air.

Ensure there is a sufficient water supply.

Adjust float switch correctly.

Hold pump at an angle when sub- merging.

Pump runs continuously:

ξFloat switch does not reach lower position.

Make sure the float switch can move unrestricted.

9. Repairs

ADanger!

Repairs to electric tools must

only be carried out by a qualified electrician!

ENGLISH

Electric tools in need of repair can be sent to an authorised service center in your country. See spare parts list for address.

Please attach a description of the fault to the electric tool.

10. Environmental Protection

The packaging of the pump can be 100 % recycled.

Worn out power tools and accessories contain considerable amounts of valua- ble raw and plastic materials, which can be recycled.

These instructions are printed on chlo- rine-free bleached paper.

11. Technical Specifications

Mains voltage

V

230 α 1

 

 

 

Frequency

Hz

50

 

 

 

Rated output

W

1000

 

 

 

Rated current

A

4.4

 

 

 

Fuse protection min. (time-lag or L-type circuit breaker)

A

10

 

 

 

Running capacitor

ΠF

12.5

 

 

 

Rated speed

min-1

2800

Pump capacity max.

l/h

7500

 

 

 

Delivery head max.

m

36

 

 

 

Delivery pressure max.

bar

3.6

 

 

 

Immersion depth max.

m

10

 

 

 

Standing water max.

mm

30

 

 

 

Temperature of the primed medium max.

°C

35

 

 

 

Degree of protection

 

IP 68

 

 

 

Protection class

 

I

 

 

 

Insulation class

 

B

 

 

 

Materials

 

 

Pump casing

 

Polypropylene

Pump shaft

 

Stainless steel

Impeller

 

Noryl

 

 

 

Power cable (HO 7 RN-F)

m

15

 

 

 

Discharge port (AG=male, IG=female)

 

1" IG

 

 

 

Dimensions (pump casing)

 

 

Height

mm

470

Diameter

mm

150

 

 

 

Weight

kg

8.2

 

 

 

Max. length of extension cable

 

 

at 3 x 1.0 mm2 lead cross-section

m

30

at 3 x 1,5 mm2 lead cross-section

m

50

11

Page 11
Image 11
Metabo TDP 7500 S English, Repairs, Environmental Protection, Technical Specifications, Motor hums but does not start