METRObility Optical Systems 8100 manual Redundant Link Control, Configuring Link Pairs

Models: 8100

1 74
Download 74 pages 22.59 Kb
Page 32
Image 32

Redundant Link Control

The Redundant Link Control Menu allows configuring of up to 24 pairs of redundant links within a stack. Users can ensure that all packets sent will reach their destination even in the event of a hub failure when Link Pairs are configured. Configuring Link Pairs requires naming the Link Pair with a numeral from 1~24, configuring primary and secondary groups and ports, setting the Link Switch Notify, setting the Status, and, finally, saving the configuration.

Redundant Link Control Menu

Configuring Link Pairs

1.Select the Link Pair number from 1 – 24.

2.Enter the Primary Link Group (1 – 6).

3.Enter the Primary Link Port (1 – 12/24).

4.Enter the Secondary Link Group (1 – 6).

NOTE: You can configure and save the Secondary Link Group and the Primary Link Group as the same hub, however this will be of no use in the event of a hub failure.

5.Enter the Secondary Link Port (1 – 12/24).

32 CenturyStack® 8100 Managed Hub

Page 32
Image 32