Versions “11” and “24” Pin Assignments for RS-485

The version “11” and “24” scanners head cables are terminated with a male 25-pin D-type connector. To connect the scanner to the host device, may require a communication cable. The communication cable may include a connection for a transformer or it may be designed to draw power directly from the host device. This item can be ordered at the same time scanner is purchased.

The version “11” and “24” scanners are designed to be used primarily with IBM® 46XX series of electronic cash registers. It can also be configured to communicate using the full RS-232 and OCIA protocol.

The following is a list of the pin assignments. The pin numbers are impressed on the head cable’s connector.

Pin

Function

1

AC Shield Ground

2

RS-232 Receive Input

3

RS-232 Transmit Output

4

CTS Input

5

RTS Output

6

Reserved

7

Signal Ground

8 - 12

Reserved

13

Earth Ground

14

Power Ground 1

15

468X -B

16

468X +A

17

OCIA Clock In Return

18

OCIA Clock In

19

Power (11 - 30 volts) DC

20

DTR Input

21

OCIA Clock Out

22

OCIA Clock Out Return

23

OCIA RDATA

24

OCIA RDATA Return

25

Power Ground 2