6
INTRODUCTION

MS2200 SERIES DESIGN SPECIFICATIONS

Design Specifications
Operational
Light Source: VLD 650 nm
Peak Laser Power: <1.5 mW
Maximum IR LED Output: 50μW per IEC 60825-1 measurement procedure
Horizontal Depth of Field: 0 mm - 152 mm (0”- 6”) for 0.33 mm (13 mil) Bar Code
Vertical Depth of Field: 0 mm - 216 mm (0”- 8.5”) for 0.33 mm (13 mil) Bar Code
Scan (Scan) Speed: 5400 Scan Lines per Second (Scan) Zone: 360°
No. of Scan Lines: 54 (38 Horizontal / 16 Vertical)
Motor Speed: 6000 / 6000 RPM (Horizontal / Vertical )
Min Bar Width: 0.127 mm (5.0 mil)
Decode Capability: All Standard 1-D Bar Codes, RSS-14, RSS-Expanded, and RSS-14 Limited Bar Codes
System Interfaces: RS232, Aux RS232, IBM468x/469x, USB, and OCIA
Print Contrast: 35% Minimum Reflectance Difference
No. Characters Read: Up to 80 data characters. Maximum number will vary based on symbology and density.
Beeper Operation: 7 Tones or No Beep; 3 Volume Settings
Blue White Amber
Indicators (LED) Laser ON, Ready to Scan Good Read, Decoding Scale at Zero
Mechanical
MS2220 L x W x H: 399 mm (15.7") [L] 292 mm (11.5") [W] 130 mm (5.12") [Tower Height]
Depth (Below Counter): 100 mm (3.9")
Weight (with Platter): MS2220, 9.28 kg (20.5 lbs.)
Electrical
Voltage Supply: 2A @ +5.2V / 1A @ +12V
Power: Operating: 11.9 Watts Standby: 3.25 Watts
Current: Operating: 1.5A @ 5.2V / .3A @ 12V Standby: .44 A @ 5.2V / .08A @ 12V
DC Transformers: Class II; 5.2VDC @ 2A; 12VDC @ 1A
For Regulatory Compliance Information refer to pages 70 - 72.
Scale Capacities
Capacity: kg unit 6.0 / 15.0 kg lb. unit 15.0 / 30.0 lb.
Minimum Increments: kg unit 0.002 / 0.005 kg lb. unit 0.005 / 0.01 lb.
Maximum Static Weight: kg unit 75.0 kg lb. unit 150.0 lb.
Adjustments required: Calibration only.
Environmental
Operating Temperature: 0°C to 40°C (32°F to 104°F)
IP Rating: IP 55
Light Levels: 4842 Lux (450 foot-candles)
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% Relative Humidity, Non-Condensing
Contaminants: Sealed to resist airborne particulate contaminants.
Ventilation: None Required
Specifications are subject to change without notice.