 23
UPGRADING THE
FIRMWARE 
The Voyager series is part of Metrologic's line of scanners with flash upgradeable 
firmware.  The upgrade process requires a new firmware file supplied to the 
customer by a customer service representative
 and Metrologic's MetroSet2 
software
.  A personal computer running Windows 95 or greater with an 
available RS232 serial or USB port is required to complete the upgrade.   
 Do not use the standard cable supplied with Keyboard Wedge or 
RS485
 interface kits for firmware upgrades.  Use either cable  
#54-54014x or #53-53014x.  If using USB or RS232 for the upgrade 
process, the standard USB or RS232 cable provided with the scanner 
can be used. 
To upgrade the firmware in the MS9520/MS9540: 
1.  Plug the scanner into a serial communication port on the host system. 
2.  Start the MetroSet2 software. 
3.  Click on the plus sign (+) next to POS Scanners to expand the supported 
scanner list. 
4. Choose the Voyager/9520 N/R or Voyager/9540 N/R from the list. 
5.  Click on the Configure Scanner button. 
6. Choose Flash Utility from the options list located on the left side of the 
screen. 
7.  Click on the Open File button in the Flash Utility window. 
8.  Locate and open the flash upgrade file supplied by Metrologic. 
9.  Select the COM port that the scanner is connected to on the host system. 
10.  Verify the settings listed in the Flash Utility window. 
11.  Click on the Flash Scanner button to begin the flash upgrade. 
12.  A message will appear on the screen when the upgrade is complete.  
Metrologic's customer service department can be reached at 
1-800-ID-METRO or 1-800-436-3876. 
MetroSet2 is available for download, at no additional cost, from 
http://www.metrologic.com/corporate/download. 