 27
  27T
ROUBLESHOOTING 
G
UIDE
No power is being 
supplied to the unit. 
Check the transformer, the outlet 
and power strip.  Make sure the 
cable is plugged into the unit. 
The unit has no 
LEDs, beep or laser.  No power is being 
supplied to the unit 
from host. 
Some host systems cannot supply 
enough current to power Voyager.  
A power supply may be needed. 
At power up the 
unit beeps 2 times 
and alternately 
flashes the LEDs.  
There is a ROM 
failure.  A flash ROM upgrade is required. 
At power up the 
unit beeps 3 times.  
There is a non-
volatile RAM failure. 
At power up there 
is a continuous 
razz tone. 
There has been a 
diagnostic failure. 
At power up there 
is a razz tone and 
the green* LED 
flashes.   
There is a VLD 
failure. 
At power up there 
is a razz tone and 
both LEDs flash.
There is a scanning 
mechanism failure. 
Contact a Metrologic service 
representative. 
The unit scans, 
communicates, and 
beeps twice. 
The same symbol 
timeout is set too 
short. 
Adjust the same symbol timeout for 
a longer time. 
The unit powers up, 
but does not beep. 
The beeper may be 
disabled or no tone 
has been selected. 
Enable beeper and select a tone. 
The unit powers up, 
but does not scan 
and/or beep. 
The unit is trying to 
scan a particular 
symbology that is 
not enabled. 
UPC/EAN, Code 39, interleaved 2 of 
5, Code 93, Code 128 and Codabar 
are enabled by default. Verify that 
the type of bar code being read has 
been selected. 
*
  In some custom units, the standard green LED has been replaced with a blue LED and the red 