Operational

 

 

 

 

 

 

 

Depth of Scan Field

203mm to 457mm (8" to 18")

 

Scan Speed

Model 870 1250 scan lines per second

 

 

Model 875: 450 scan lines per second

 

Scan Pattern

Model 870: Omnidirectional (20 interlocking lines)

 

 

Model 875: 6-line raster

 

Indicators

LED: green=on ready to scan; red=good read

 

Beeper Operation

Selection of 3 tones for “Good Read”

 

Maintenance Required

Clean window periodically

 

Decode Capability

Autodiscriminates

 

System Interfaces

RS-232C; Light Pen Emulation; OCIA

 

Optional Interfaces

Opto coupled 6 amp Us and Canada, 5 amps EEA

 

 

countries TRIAC output; object sensor input

 

Print Contrast

35% minimum reflectance difference

 

Roll, Pitch, Yaw

360E, 60E, 60E

 

 

 

 

 

 

 

 

Environmental

 

 

 

 

 

 

 

Storage Temperature

-40EC to 60EC (-40EF to 140EF)

 

Operating Temperature

0EC to 35EC (32EF to 95EF)

 

Humidity

5% to 95% relative humidity, non-condensing

 

Light Levels

Up to 3200 foot candles - works in direct sun

 

Ventilation

None required

 

Shock

100g for 1ms

 

ESD

8kV IEC 801-2

 

Contaminants

Protects against dust, falling dirt, and dripping

 

 

non-corrosive liquid

 

 

 

Patents Pending

 

Specifications subject to change without notice.