Pole-Mounting MINAs with the MYA-MINA
Up to two MINA loudspeakers can be pole-mounted with 
the MYA-MINA mounting yoke. For pole-mount applica-
tions, the yoke support up to 30 degrees of downtilt and 
severe uptilts of up to 90 degrees. When pole-mounting 
MINAs with the yoke, a third-party pole-mount adapter is 
required.
CAUTION: When mounting the MYA-MINA on 
a pole, make sure the pole and pole-mount 
adapter have been rated to support the full weight of 
the yoke and loudspeakers. Observe all safety pre-
cautions specified by the pole and pole-mount 
adapter manufacturer.
MUB-MINA U-BRACKET
The MUB-MINA U-bracket was primarily designed for aim-
ing a single MINA loudspeaker in floor- and ceiling-mount 
configurations. However, the U-bracket is strong enough to 
fly arrays of up to three cabinets, or stack up to two cabinets 
in floor- and pole-mount configurations. The U-bracket can 
also be flown from trusses using C-clamps or equivalent. 
For flying and groundstacking larger arrays, the MG-MINA 
grid is recommended; for applications requiring continuous 
adjustability or greater downtilt and uptilt angles, the 
MYA-MINA mounting yoke is recommended.
NOTE: For complete information on configura-
tion and load ratings for the MUB-MINA, as 
well as for other rigging accessories, refer to the 
MG-MINA Assembly Guide (PN 05.207.101.01) avail-
able at www.meyersound.com.
The MUB-MINA U-bracket’s mounting holes and mounting 
slot provide maximum flexibility for the loudspeaker’s uptilt 
and downtilt. For flown applications, the MUB-MINA can be 
oriented for either maximum downtilt (with the slot near the 
front of the loudspeakers) or maximum uptilt (with the slot 
near the rear of the loudspeakers).
■For a single flown cabinet, the MUB-MINA supports con-
tinuos angles of 0 to –20 degrees in the maximum down-
tilt orientation, and angles of +10 to –10 degrees in the 
maximum uptilt orientation.
■For multiple flown cabinets, the MUB-MINA supports 
fixed angles of +10, 0, –5, –10 and –20 degrees (with 
either orientation).
NOTE: For multiple flown cabinets, the 
MUB-MINA slot is not recommended for vari-
able adjustments since the angle could change over 
time due to the weight of the cabinets.
NOTE: For illustrations showing which 
MUB-MINA mounting holes and slot configura-
tions to use to achieve specific angles, refer to the 
MG-MINA Assembly Guide (PN 05.207.101.01) avail-
able at www.meyersound.com.
Pole-Mounted MYA-MINA with MPA-2 Adapter and Two MINAs
!
Ceiling-Mounted MUB-MINA with One MINA