9

Fig. 3 – Coverage of Sprayer

3.Calculate the area treated by the sprayer per minute. Fig. 3 shows the sprayer being operated over a field crop.

If the operator is walking at S Km/Hr this corresponds to 1000 x S metres/hour:

Distance travelled

=

1000 x S

metres/minute

 

 

60

 

If the width of the swath is W metres, then the area treated per minute is:

Area treated

=

1000 x S x W

 

sq metres/minute

 

 

60

 

 

 

This is converted to hectares by dividing by 10,000:

 

Area treated

=

1000 x S x W

=

S x W

ha/minute

 

 

60 x 10,000

 

600

 

This gives the standard formula for calculating the coverage of a sprayer:

Area/min

=

Swath Width (m) x Speed (Km/Hr)

ha/min

 

 

600

 

MICRONAIR AU8000 SPRAYER

Page 11
Image 11
Micron Technology AU8000 manual Coverage of Sprayer