17

After dismantling the atomiser, the following should be checked:

Gauze (104)

– Free of dents or chemical contamination

Bearings (113)

Both in good condition. If one bearing is faulty, both

 

 

must be replaced

Tolerance Rings (116)

– Not cracked or deformed

Bearing Spacers

Not corroded or worn

(106 and 107)

 

 

V-Ring Seal (114)

– In good condition and not cut or worn

Nilos Ring (115)

Not worn or bent

Any worn and damaged parts must be replaced with genuine Micronair spares. Any attempt at local repair or the use of substitute parts could seriously damage the unit and impair its performance.

The procedure to re-assemble the atomiser and sprayhead is the reverse of the dismantling procedure. It is important that the following points are observed.

1.Fill the recess of the Nilos ring and the brass sealing (110) ring with grease. The bearings, spacers and lip of the V-Ring should also be coated with a thin film of grease before assembly.

NOTE: When new bearings are fitted a new Nilos ring should be fitted.

2.The bearings must be pressed squarely into the hub and must not be allowed to become mis-aligned. They must NOT be driven in with a hammer.

3.The clamp ring (103) must be assembled in the correct position with the dimples in the ring and hub body aligned.

NOTE: Item numbers 1 – 20 refer to Fig. 5 and item numbers 101 – 122 refer to Fig. 6.

MICRONAIR AU8000 SPRAYER

Page 19
Image 19
Micron Technology manual Micronair AU8000 Sprayer