Middleby Marshall 60254 Iii. Quick Reference Troubleshooting, Symptom, Problem, Solution, turn On

Models: 60254

1 36
Download 36 pages 51.84 Kb
Page 25
Image 25
III. QUICK REFERENCE: TROUBLESHOOTING

III. QUICK REFERENCE: TROUBLESHOOTING

 

 

SYMPTOM

 

PROBLEM

 

SOLUTION

 

 

 

 

 

Oven will not

No electrical power

• Check that the circuit breaker/fused disconnect is on. Make

turn On.

 

 

 

 

sure the emergenct stop button is on.

Oven will not

 

Faulty contactor

Replace contactor.

heat.

 

 

 

 

 

 

 

Faulty heater element

Replace element.

Oven is operating, but little

 

Air fingers may be as-

• Turn oven off, and allow to cool. Reassemble fingers correctly.

or no air is coming from

 

sembled incorrectly after

 

 

the fingers.

 

cleaning.

 

 

Conveyor will not move.

 

Conveyor may be jammed.

• Turn oven off, and allow to cool. Check conveyor for blockage.

SCREEN ALERTS

 

 

 

 

SYMPTOM

 

PROBLEM

SOLUTION

 

 

 

 

 

High Control Compartment

 

Clean and replace the front

• Failure to do this will eventually shut down the oven due to

Temperature

 

fan filters.

excessive temperature.

Main Blower problem

 

The computer has detected

• This should be corrected by a qualified service technician.

or Combustion Blower

 

a problem with either the

 

problem.

 

main, or burner blowers.

 

Control Over Temp

Front filters are clogged

• Clean or replace filters.

Front belt jammed

Front belt has stopped

• Remove obstruction, and restart oven.

 

 

 

 

• If no obstruction, call service.

Rear Belt jammed

Rear belt has stopped

• Remove obstruction, and restart oven.

 

 

 

 

• If no obstruction, call service.

High Temp Error

Thermocouple or

• Call service

 

PLC malfunction

 

Belt off-Oven not

Normal operation until

 

in temperature

Oven reaches operating

 

 

temperature

 

Energy Saving Mode 1

Normal operation

 

Energy saving mode 2

Normal operation

 

Energy saving Mode 3

Normal operation

 

21

P/N 60254 September 28, 2012

Page 25
Image 25
Middleby Marshall 60254 Iii. Quick Reference Troubleshooting, Symptom, Problem, Solution, Screen Alerts, turn On, heat