Figure | F. | Adjusting the Minimum Pressure Setting | |
|
| 1. | Disconnect pressure feedback connection (if appcable). |
|
| 2. | Connect a suitable pressure gauge to pipe line or to outlet |
|
|
| pressure tap of gas control concerned, to measure burner |
|
|
| pressure (measuring point must be as near to burner as |
|
|
| possible). |
|
| 3. | Disconnect electrical connection of the Moduplus®. |
|
| 4. | Energize operator, set control in operation and wait until |
|
|
| an outlet pressure is recorded on pressure gauge. |
|
| 5. | If minimum rate pressure needs adjustment, use a 5 mm |
|
|
| wrench to turn adjustment screw for minimum pressure |
|
|
| setting (clockwise to increase or |
|
|
| decrease pressure), until the desired minimum outlet |
|
|
| pressure is obtained. |
|
| 6. | Check if main burner lights easily and reliable at minimum |
|
|
| pressure. |
|
| 7. | Reconnect pressure feedback connection (if appcable). |
|
| 8. | Close pressure tap screw. |
|
| G. | Checkout |
|
| After any adjustment, set appliance in operation and observe | |
|
| through a component cycle to ensure that burner system com- | |
|
| ponents function correctly. | |
|
| NOTE: The installer MUST verify oven operation prior to put- | |
|
|
| ting oven into service. |
|
| H. | Maintenance |
|
| It is recommended to check yearly the minimum and the maxi- | |
|
| mum setting and readjust them if necessary. | |
Figure |
|
| |
Adjustment Screw (5 mm) | Adjustment Screw |
|
|
for minimum pressure | (8 mm) for maxi- |
|
|
setting | mum |
|
|
| pressure |
|
|
| setting |
|
|
19 | P/N 60250 September 28, 2012 |