ENGLISH
SECTION 2 - INSTALLATION
V. GAS SUPPLY
CAUTION
DURINGPRESSURETESTINGNOTETHEFOLLOWING:
1.The oven and its individual shutoff valve must be discon- nected from the gas supply piping system during any pressure testing of that system at test pressure in excess of 1/2 psi (3.45 kPa).
2.The oven must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psi (3.45 kPa).
3.If incoming pressure is over 14" W.C. (35mbar), a separate regulator MUST be installed in the line BEFORE the individual shutoff valve for the oven.
WARNING: To prevent damage to the control valve regu- lator during initial turn- on of gas, it is very important to open the manual shutoff valve very slowly.
After the initial gas
A.Gas Utility Rough-In Recommendations
The following gas system specifications are STRONGLY RECOMMENDED. Deviating from these recommendations may affect the baking performance of the oven.
Gas Meter - 650 cfh (307l/min) meter
Gas Line
•DEDICATED LINE from the gas meter to the oven
•2" (50.8mm) pipe for natural gas
•
•Maximum length: 200' (61m). Each 90° elbow equals 7' (2.13m) of pipe.
B.Connection
Check the oven’s gas supply requirements before making the gas utility connection. Gas supply requirement are listed on the oven’s serial plate and in Table
Check the serial plate to determine the type of gas (Propane or Natural) to be used with the oven.
Refer to the instructions in the gas hose package (included in the Installation Kit) before connecting the gas line. One gas line connection method is shown in Figure
Inlet, regulated, and pilot gas pressure readings can be taken using a digital tube manometer at the tap location shown in Figure
NOTE: The installation must conform with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI
Certain safety code requirements exist for the installation of gas ovens; refer to the beginning of Section 2 for a list of the installation standards. In addition, because the oven is equipped with casters, the gas line connection shall be made with a connector that complies with the Standard for Connectors for Movable Gas
Appliances, ANSI Z21.69 (in U.S.A.), as well as a
C.Gas Conversion
Where permitted by local and national codes, it is possible to convert ovens from natural to propane gas, or from propane to natural gas. Use the appropriate Middleby Gas Conversion Kit for the specific oven model.
CAUTION: The terms of the oven’s warranty require all start- ups, conversions and service work to be per- formed by a Middleby Authorized Service Agent.
D.PS536 Propane Conversion
Two items have to be changed, to change the oven to LP:
1.Replace main orifices.
2.Adjust main gas regulator per instructions below.
Disconnect the manifold union closest to the main burner, and remove the manifold assembly (four screws). Slide out the manifold assembly (leaving the ignition and sense wires con- nected). Replace the main orifices.
Replace the main orifices on the manifold assemblies with the LP units, and replace the manifold assembly. Reconnect the union.
E.Adjusting the Maximum Pressure Setting
1.Disconnect pressure feedback connection (if appcable).
2.Connect a suitable pressure gauge to pipe line or to outlet pressure tap of gas control concerned, to mea- sure burner pressure (measuring point must be as near to burner as possible).
3.Make sure that the appliance is in operation and the Moduplus® coil is energized with maximum current.
4.If maximum rate pressure needs adjustment, use an 8 mm wrench to turn adjustment screw for maximum pressure setting (clockwise to increase or
Figure 2-15 - Flexible Gas Hose Installation
1/2" gas |
| |
pipe nipple |
| |
gas pipe |
| |
| To Gas | |
| reducer | |
| Supply | |
|
| |
|
| Pipe |
| 3/4" gas |
|
| pipe nipple |
|
1/2" gas line |
|
|
tee with | 90° |
|
pressure tap |
| |
| Elbow |
|
Gas
Shutoff
Valve
| Flexible | Individual gas | |
Quick- | connection for | ||
Gas Hose | |||
each oven | |||
disconnect | |||
| |||
| cavity | ||
device |
| ||
|
|
14