![](/images/new-backgrounds/1071732/71732129x1.webp)
|
| Frequently asked questions | |
|
|
|
|
|
|
|
|
Fault | Possible cause and solution | ||
|
|
|
|
Fault 73 | The brew unit cannot reset to the correct position or it is | ||
or | clogged and the ground coffee cannot be processed. | ||
"Check brew unit" | See if you can remove the brew unit (see "Cleaning and | ||
|
| care – Brew unit"). | |
| If you can remove the brew unit, clean it (see "Cleaning | ||
|
| and care – Brew unit"). | |
|
|
|
|
|
|
|
|
Push the coffee ejector of the brew unit into the standard position (see illustration).
Reinsert the waste unit and the water container. Do not insert the brew unit. Close the door and turn on the coffee system using the On/Off sensor .
The brew unit motor will automatically move to the correct position.
When the message "Insert brew unit" is displayed, open the door and reinsert all the parts into the coffee system. Close the front door.
| If you cannot remove the brew unit: |
| Touch the On/Off sensor to turn off the coffee system. |
| Wait about 2 minutes and then turn the system back on. |
|
|
Fault 227 - 230, | The automatic dispenser adjustment is malfunctioning. |
Fault 233 | To confirm the message, press OK. |
| The automatic dispenser adjustment will be deactivated |
| during beverage preparation as long as the system remains |
| turned on. You can still make beverages. |
65