Miele 09 968 280 installation instructions Condensate trap, Reducing Collar, Exhaust duct

Models: 09 968 280

1 36
Download 36 pages 46.44 Kb
Page 31
Image 31
Condensate trap

Exhaust duct

Condensate trap

In addition to insulating the exhaust duct, we recommend installing a condensate trap to collect and evaporate any condensate which might accumulate.

Condensate traps are available for exhaust ducts with a diameter of 5" (125 mm) or 6" (150 mm).

When installing a condensate trap, make sure that it is positioned vertically and, if possible, directly above the hood outlet duct collar. The arrow on the housing indicates the direction of airflow.

Reducing Collar

(optional accessory)

If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed. It reduces the air flow to less than 400 CFM. Check local building codes for max. CFM requirements.

Push the Reducing Collar on the exhaust port of the fan.

Push the exhaust hose over it.

Fix both with a hose clamp.

31

Page 31
Image 31
Miele 09 968 280 installation instructions Condensate trap, Reducing Collar, Exhaust duct